SPECIFIC VEHICLE ALARM FITTING INSTRUCTIONS REV. 00
www.cobra.it
MAKE TOYOTA MOD. LAND CRUISER YEAR 03
PETROL
DIESEL
X
ALARM/SIREN
POSITION
Position the compact alarms and the sirens on the support of the shock absorber,
driver’s side.
CENTRAL UNIT POSITION
Position the modular sistems and the modules under the dashboard, on the left of the steering
column, near the fuse box.
POWER SUPPLY
+30: connect to the BLUE/WHITE wire, in the 2 way connector, located in the middle of the
fuse box, on the left of the steering column.
-31: connect to a ground terminal located behind the driver’s side bulkhead.
IGNITION WIRE
+15/54: connect to the BLUE/YELLOW wire, in the 2 way connector, located in the middle of
the fuse box, on the left of the steering column.
DIRECTION INDICATORS
Connect to the BLUE/BLACK and BLUE/YELLOW wires, in the 16 way black connector, in the
left part of the fuse box. As alternative: connect to the BLUE/BLACK and BLUE/YELLOW
wires, in the 4 way white connector, behind the fuse box.
ELECTRIC WINDOWS
It is not possible to make the connection of the electric windows as the windows central units
lose the programming.
CENTRAL DOORS LOCKING Negative control signal
Connect to the BLUE wire (lock) and to the GREEN wire (unlock) in the connector coming out
of the unlock/lock push-button on the driver’s side door.
IMMOBILISATION POINT
Fuel pump
Cut the BLACK/ORANGE wire, at the position nr.2, in the 24 way connector in the fuse box.
STARTER
+50: Cut the GREEN wire, at the position nr.8, in the 8 way white connector coming out of the
ignition key.
BONNET SWITCH
Install an additional switch on the headlamp support plate.
DOORS SWITCH
Connect to the wires: WHITE/GREEN, RED/YELLOW, WHITE/GREEN, RED/YELLOW in the
22 way white connector, on the side of the fuse box. Divide the lines with 4 diodes 1N4004.
BOOT SWITCH
Connect to the RED/BLUE wire, in the 22 way white connector, on the side of the fuse box
Note: This information is not binding, therefore it must be considered only an example for installation purposes that must be executed