xgb_cnet.pdf

(7123 KB) Pobierz
Right choice for ultimate yield
LSIS strives to maximize customers' profit in gratitude of choosing us for your
partner.
Programmable Logic Controller
XGB Cnet I/F
XGT Series
User’s Manual
Main unit
Built-in Cnet
Cnet I/F
module
XBL-C41A
XBL-C21A
XBM-DR16S
XBM-DN16S
XBM-DN32S
XBC-DR32H
XBC-DN32H
XBC-DR64H
XBC-DN64H
LS values every single customer.
Quality and service come first at LSIS.
Always at your service, standing for our customers.
10310000736
HEAD OFFICE
LS tower, Hogye-dong, Dongan-gu, Anyang-si, Gyeonggi-do
1026-6, Korea http://eng.lsis.biz
Tel. (82-2)2034-4689, 4888 Fax.(82-2)2034-4648
LS Industrial Systems Tokyo Office >> Japan
Address: 16F, Higashi-Kan, Akasaka Twin Towers 17- 22,
2-chome, Akasaka, Minato-ku, Tokyo 107-8470, Japan
Tel: 81-3-3582-9128 Fax: 81-3-3582-2667
e-mail: j schuna@lsis.biz
LS Industrial Systems Dubai Rep. Office >> UAE
Address: P.O.BOX-114216, API World Tower, 303B, Sheikh
Zayed road, Dubai, UAE. e-mail: hwyim@lsis.biz
Tel: 971-4-3328289 Fax: 971-4-3329444
LS-VINA Industrial Systems Co., Ltd. >> Vietnam
Address: LSIS VINA Congty che tao may dien Viet-Hung
Dong Anh Hanoi, Vietnam e-mail: srjo@hn.vnn.vn
Tel: 84-4-882-0222 Fax: 84-4-882-0220
LS Industrial Systems Hanoi Office >> Vietnam
Address: Room C21, 5th Floor, Horison Hotel, 40 Cat Linh,
Hanoi, Vietnam
Tel: 84-4-736-6270/1 Fax: 84-4-736-6269
Dalian LS Industrial Systems co., Ltd, >> China
Address: No. 15 Liaohexi 3 Road, economic and technical
development zone, Dalian, China e-mail: l ixk@lgis.com.cn
Tel: 86-411-8273-7777 Fax: 86-411-8730-7560
LS Industrial Systems (Shanghai) Co., Ltd. >> China
Address: Room E-G, 12th Floor Huamin Empire Plaza,
No. 726, West Yan’an Road, Shanghai, China
Tel: 86-21-5237-9977
LS Industrial Systems(Wuxi) Co., Ltd. >> China
Address: 102-A National High & New Tech Industrial
Development Area, Wuxi, Jiangsu, China e-mail: Xugh@lgis.com.cn
Tel: 86-510-534-6666 Fax: 86-510-522-4078
LS Industrial Systems Beijing Office >> China
Address: B-tower 17th Floor, Beijing Global Trade Center building,
No. 36, BeiSanHuanDong-Lu, DongCheng-District, Beijing, China
Tel: 86-10-5825-6025
LS Industrial Systems Guangzhou Office >> China
Address: Room 1403, 14F, New Poly Tower, 2 Zhongshan Liu
Rad, Guangzhou, China e-mail: zhangch@lgis.com.cn
Tel: 86-20-8326-6754 Fax: 86-20-8326-6287
LS Industrial Systems Chengdu Office >> China
Address: Room 2907, Zhong Yin B/D, No. 35, Renminzhong(2)-
Road, Chengdu, China e-mail: hongkonk@vip.163.com
Tel: 86-28-8612-9151 Fax: 86-28-8612-9236
LS Industrial Systems Qingdao Office >> China
Address: 12th Floor, Guodong building, No52 Jindun Road,
Chengdu, China e-mail: bellkuk@hanmail.net
Tel: 86-532-580-2539 Fax: 86-532-583-3793
z Read this manual carefully before
installing, wiring, operating, servicing
or inspecting this equipment.
z Keep this manual within easy reach
for quick reference.
LS Industrial Systems constantly endeavors to improve its product so that
Information in this manual is subject to change without notice.
XGB Cnet/2008. 7
Copyrights 2006 LS Industrial systems Co., Ltd All Rights Reserved.
904660972.051.png 904660972.061.png 904660972.072.png 904660972.082.png 904660972.001.png 904660972.002.png 904660972.003.png 904660972.004.png 904660972.005.png 904660972.006.png 904660972.007.png 904660972.008.png 904660972.009.png 904660972.010.png 904660972.011.png 904660972.012.png 904660972.013.png 904660972.014.png 904660972.015.png 904660972.016.png 904660972.017.png 904660972.018.png 904660972.019.png 904660972.020.png 904660972.021.png 904660972.022.png 904660972.023.png 904660972.024.png 904660972.025.png 904660972.026.png 904660972.027.png 904660972.028.png 904660972.029.png 904660972.030.png 904660972.031.png 904660972.032.png 904660972.033.png 904660972.034.png 904660972.035.png 904660972.036.png 904660972.037.png 904660972.038.png 904660972.039.png 904660972.040.png 904660972.041.png 904660972.042.png 904660972.043.png 904660972.044.png 904660972.045.png 904660972.046.png 904660972.047.png 904660972.048.png 904660972.049.png 904660972.050.png 904660972.052.png 904660972.053.png 904660972.054.png 904660972.055.png 904660972.056.png 904660972.057.png 904660972.058.png 904660972.059.png
 
Safety Instruction
Before using the product …
For your safety and effective operation, please read the safety instructions
thoroughly before using the product.
Safety Instructions should always be observed in order to prevent accident
or risk by using the product properly and safely.
Precautious measures can be categorized as “Warning” and “Caution”, and
each of the meanings is as follows.
This symbol indicates the possibility of serious injury
or death if some applicable instruction is violated
Warning
This symbol indicates the possibility of severe or
slight injury, and damages in products if some
applicable instruction is violated
Caution
Moreover, even classified events under its caution category may develop into
serious accidents depending on situations. Therefore we strongly advise users
to observe all precautions in a proper way just like warnings.
The marks displayed on the product and in the user’s manual have the
following meanings .
Be careful! Danger may be expected .
Be careful! Electric shock may occur .
After reading this user’s manual, it should be stored in a place that is visible
to product users.
904660972.060.png 904660972.062.png 904660972.063.png 904660972.064.png 904660972.065.png 904660972.066.png 904660972.067.png
Safety Instruction
Safety Instructions when designing
Warning
Please, install protection circuit on the exterior of PLC to protect
the whole control system from any error in external power or PLC
module. Any abnormal output or operation may cause serious problem
in safety of the whole system.
-
Install applicable protection unit on the exterior of PLC to protect
the system from physical damage such as emergent stop switch,
protection circuit, the upper/lowest limit switch, forward/reverse
operation interlock circuit, etc.
-
If any system error (watch-dog timer error, module installation error,
etc.) is detected during CPU operation in PLC, the whole output is
designed to be turned off and stopped for system safety. However,
in case CPU error if caused on output device itself such as relay or
TR can not be detected, the output may be kept on, which may
cause serious problems. Thus, you are recommended to install an
addition circuit to monitor the output status.
Never connect the overload than rated to the output module nor
allow the output circuit to have a short circuit , which may cause a
fire.
Never let the external power of the output circuit be designed to
be On earlier than PLC power , which may cause abnormal output or
operation.
In case of data exchange between computer or other external
equipment and PLC through communication or any operation of
PLC (e.g. operation mode change), please install interlock in the
sequence program to protect the system from any error . If not, it
may cause abnormal output or operation.
904660972.068.png 904660972.069.png 904660972.070.png
Safety Instruction
Safety Instructions when designing
Caution
I/O signal or communication line shall be wired at least 100mm
away from a high-voltage cable or power line. If not, it may cause
abnormal output or operation.
Safety Instructions when designing
Caution
Use PLC only in the environment specified in PLC manual or
general standard of data sheet. If not, electric shock, fire, abnormal
operation of the product or flames may be caused.
Before installing the module, be sure PLC power is off. If not,
electric shock or damage on the product may be caused.
Be sure that each module of PLC is correctly secured. If the
product is installed loosely or incorrectly, abnormal operation, error or
dropping may be caused.
Be sure that I/O or extension connecter is correctly secured. If
not, electric shock, fire or abnormal operation may be caused.
If lots of vibration is expected in the installation environment,
don’t let PLC directly vibrated. Electric shock, fire or abnormal
operation may be caused.
Don’t let any metallic foreign materials inside the product , which
may cause electric shock, fire or abnormal operation. .
904660972.071.png 904660972.073.png 904660972.074.png 904660972.075.png 904660972.076.png
Safety Instruction
Safety Instructions when wiring
Warning
Prior to wiring, be sure that power of PLC and external power is
turned off. If not, electric shock or damage on the product may be
caused.
Before PLC system is powered on, be sure that all the covers of
the terminal are securely closed. If not, electric shock may be caused
Caution
Let the wiring installed correctly after checking the voltage rated
of each product and the arrangement of terminals. If not, fire,
electric shock or abnormal operation may be caused.
Secure the screws of terminals tightly with specified torque when
wiring. If the screws of terminals get loose, short circuit, fire or abnormal
operation may be caused.
*
Surely use the ground wire of Class 3 for FG terminals, which is
exclusively used for PLC . If the terminals not grounded correctly,
abnormal operation may be caused.
Don’t let any foreign materials such as wiring waste inside the
module while wiring, which may cause fire, damage on the product
or abnormal operation .
904660972.077.png 904660972.078.png 904660972.079.png 904660972.080.png 904660972.081.png