MGSP-EP11.pdf
(
2019 KB
)
Pobierz
MG5000 V2.31
MG5050 V2.31
SP5500 V2.31
SP6000 V2.31
SP7000 V2.31
Programming Guide
We hope this product performs to your complete satisfaction. Should you have any
questions or comments, please visit www.paradox.com and send us your comments.
Table of Contents
Table of Contents .......................................................... 2
Entering Programming Mode ......................................... 2
Codes and Panel Reset ................................................. 2
Installer Quick Menu ...................................................... 3
System Overview ........................................................... 6
Wireless Keypad Planning ............................................. 6
Hardwired System Planning .......................................... 7
Wireless System Planning ............................................ 8
Zone Programming ...................................................... 10
Keypad Programming .................................................. 16
Programmable Output Programming ........................... 17
User Programming ...................................................... 24
2-Way Remote Indicators (MG-REM2) ........................ 27
Wireless Repeater Programming (MG-RPT1) ............. 28
Wireless Keypad Programming (MG32LRF) ............... 31
LCD Keypad Labels (MG32LCD) ................................ 33
System Programming ...................................................35
Daylight Savings Programming ....................................37
Partition Programming .................................................38
Communication Programming ......................................39
WinLoad Programming ................................................44
Other Settings and Modes ...........................................44
Appendix 1: Ademco Contact ID Report Codes ...........45
Appendix 2: Automatic Report Code List .....................47
Appendix 3: Data Entry & Display ................................49
Trouble Display ............................................................50
Installer Function Keys .................................................50
Hardware Connections .................................................51
Connecting to WinLoad ................................................54
Updating Firmware Using WinLoad .............................54
Metal Box Installation ...................................................55
More detailed information can be found in the
Reference & Installation Manual,
which can be downloaded from our website
at paradox.com.
Warning or important information.
Suggestion or reminder.
Quick Menu (see page 3)
Entering Programming Mode
IMPORTANT: StayD Mode must be deactivated in order to enter programming mode. Press [
OFF
] + [
CODE
] + [
OFF
] to
deactivate StayD.
1.
Press
[
ENTER
]
2.
Enter your
[
INSTALLER
CODE
]
or
[
MAINTENANCE
CODE
]
3.
Enter 3-digit
[
SECTION
]
you wish to program
4.
Enter required
[
DATA
]
Codes and Panel Reset
Installer Code (Default: 0000 / 000000)
The Installer code is used to enter programming mode, which allows you to program everything
except
user codes. To change the default code, go to section [397] on page 24 and refer to sec-
tion [701] option [1] on page 35.
Maintenance Code (No Default)
The Maintenance code is used to enter programming mode, which allows you to
program everything
except
for user codes and communication settings (sections [395], [397],
[398], [815], [816], [817], [910], and [911]). To set the default code, go to section [398] on
page 24 and refer to section [701] option [1] on page 35.
System Master Code (Default: 1234 / 123456)
The System Master code can use any arming method and can program user codes. To change
the default code, go to section [399] on page 24 and refer to section [701] option [1] on
page 35.
Panel Reset
Press and hold the RESET switch for five seconds. When the STATUS LED flashes, press the
RESET switch within 2 seconds. However, this will not clear a bus module trouble (see section
[955]). To reset the panel to default using section programming (see section
[950]
).
IMPORTANT: When using an SP Series panel, all wireless sections and options do not apply unless an MG-RTX3 is
used in conjunction with the panel.
IMPORTANT: When using an SP6000 panel in conjunction with an MG-RTX3, all MG32LED and MG10LEDV/H keypads
must be versions 2.0 or higher.
2
Programming Guide
Installer Quick Menu
Zones
Step
Action
Details
1
+
[
INSTALLER
CODE
]
= flash. Programmed zones are lit (button or LED depending on keypad).
[
MAINTENANCE
CODE
]
may also be used.
2
[
ZONE
NUMBER
]
MG32LRF/MG32LED/MG32LCD =2 digits: 01 to 32
MG10LEDV/H =
1 digit: 1 to 0(10)
3
[E
NROLL
OR
ERASE
ZONE
]
Wireless zone = open/close cover or press learn/tamper switch. Hardwired zone = Press
[
ENTER
]. To erase a programmed zone, press [
SLEEP
] for 3 seconds.
4
[
ZONE
TYPE
]
Refer to
Zone Programming
on page 10 for the zone type (zone definition).
5
A
SSIGN
P
ARTITION
[1]
and/or
[2]
+
[
ENTER
]
Assign the zone to one or both partitions and press [
ENTER
]. By default, all zones are
assigned to partition 1. Goes to next available zone.
Notes
Partition 2 status LEDs, display the signal strength of the selected wireless zone
(4 LEDs = best signal; 1 LED = weak signal; No LEDs = hardwired panel/keypad zone)
Keypad Zone Number Assignment
(Keypad Programming)
Step
Action
Details
1
[
ENTER
] + [
INSTALLER
CODE
]
[
ARM
] +
[
STAY
] = flash.
[
MAINTENANCE
CODE
]
may also be used.
2
[
ARM
]
+ [
STAY
]
= on.
Press and hold
(3sec)
3
[
ZONE
NUMBER
]
+
[
ENTER
]
*
MG32LED/MG32LCD = 2 digits: 01 to 32
MG10LEDV/H = 1 digit: 1 to 0(10)
* To erase a keypad zone number, press
[
CLEAR
]
, then
[
ENTER
]
.
Delays
Step
Action
Details
1
+
[
INSTALLER
CODE
]
= flash.
[
MAINTENANCE
CODE
]
may also be used.
2
3
[1]
= Entry Delay 1 (sec.)
[2]
= Entry Delay 2 (sec.)
[3]
= Exit Delay (sec.)
[4]
= Bell Cut-Off (min.)
4
[000]
to
[255]
Entry/Exit Delay = seconds / Bell Cut-Off = minutes / 000 = default value
Time and Date
Step
Action
Details
1
+
[
INSTALLER
CODE
]
= flash.
[
MAINTENANCE
CODE
]
may also be used.
2
+ [5]
4
[
HH
:
MM
]
Enter time. If
HH
= 13 or more, skip to step 6.
5
[
TIME
FORMAT
]
Enter time format (
[1]
= 24hr;
[2]
= AM;
[3]
= PM).
6
[
YYYY
/
MM
/
DD
]
Enter date.
Magellan / Spectra SP
3
Walk Test Mode
Step
Action
Details
1
+
[
INSTALLER
CODE
]
= flash.
[
MAINTENANCE
CODE
]
may also be used.
2
3
[6]
Activates or deactivates Walk Test Mode.
Installer and Maintenance Codes
Step
Action
Details
1
+
[
INSTALLER
CODE
]
= flash.
[
MAINTENANCE
CODE
]
may also be used.
2
3
[7]
= Installer Code
[8]
= Maintenance Code
4
[
CODE
]
*
Enter 4- or 6-digit code.* To erase a code, press the [
SLEEP
] key for 3 seconds.
5
[
CONFIRM
CODE
]
Re-enter 4- or 6-digit code.
WinLoad
Step
Action
Details
1
+
[
INSTALLER
CODE
]
= flash.
[
MAINTENANCE
CODE
]
may also be used.
2
3
[9]
4
[
PHONE
#]
+
[
ENTER
]
*
Enter PC phone # (up to 32 digits) and press [
ENTER
].* To erase WinLoad phone #, panel
ID, and PC password, press the [
SLEEP
] key for 3 seconds.
5
[
PANEL
ID
]
Enter 4-digit Panel ID
6
[
PC
PASSWORD
]
Enter 4-digit PC Password
Monitoring Phone #
Step
Action
Details
1
+
[
INSTALLER
CODE
]
= flash.
[
MAINTENANCE
CODE
]
may also be used.
2
3
[1]
4
[
PHONE
#]
+
[
ENTER
]
*
Enter monitoring station phone # (up to 32 digits) and press [
ENTER
].* To erase monitoring
phone #, reporting format, and account #s, press the [
SLEEP
] key for 3 seconds.
5
[
PARTITION
1
ACCOUNT
#]
6
[1]
= CID
[2]
= SIA
7
[P
ARTITION
2
ACCOUNT
#]
4
Programming Guide
Communicator
Step
Action
Details
1
+
[
INSTALLER
CODE
]
= flash.
[
MAINTENANCE
CODE
]
may also be used.
2
3
[2]
= Backup Phone #
[3]
= Personal Phone #1
[4]
= Personal Phone #2
[5]
= Personal Phone #3
[6]
= Personal Phone #4
[7]
= Personal Phone #5
[8]
= Pager #
4
[
PHONE
#]
+
[
ENTER
]
*
Enter phone # (up to 32 digits) and press [
ENTER
]. Goes to next phone#, or go to step 5
if [8] = Pager # was selected. To erase a phone number.pager message, press the
[
SLEEP
] key for 3 seconds.
5
[
MESSAGE
]
+
[
ENTER
]
Step 5 for Pager # only. Enter pager message and press [
ENTER
].
Cancel Communication
Step
Action
Details
1
+
[
INSTALLER
CODE
]
= flash.
[
MAINTENANCE
CODE
]
may also be used.
2
3
[9]
Cancels all communication with WinLoad.
PGMs
Step
Action
Details
1
+
[
INSTALLER
CODE
]
= flash. Programmed zones are lit (button or LED depending on keypad).
[
MAINTENANCE
CODE
]
may also be used.
2
3
[
PGM
NUMBER
]
MG32LRF/MG32LED/MG32LCD =2 digits: 01 to 16
MG10LEDV/H =
1 digit: 1 to 0(10)
4
[
ENROLL
OR
ERASE
PGM
]
*
Wireless PGM = Open/close cover. Hardwired PGM = press [
ENTER
]. To erase a PGM,
press the [
SLEEP
] key for 3 seconds.
5
[
PGM
TYPE
]
1 = Follow Button
or
5 = Follow Bell
2 = Follow Button
or
6 = Follow Arm
3 = Follow Zone
7 = Follow Stay arm
4 = Follow Alarm
8 = Follow Sleep arm
6
If PGM type is 1, 2, 3, or 4
[
ACTIVATION
DELAY
]
1 = Follow
4 = 15 seconds
7 = 5 minutes
2 = 1 second
5 = 30 seconds
8 = 15 minutes
3 = 5 seconds
6 = 1 minute
9 = 30 minutes
If PGM type is 5
Goes to next available PGM.
If PGM type is 6, 7, or 8
[1]
and/or
[2]
+
[
ENTER
]
If system is partitioned, select partition(s) and press [
ENTER
].
Goes to next available PGM.
7
If PGM type is 1, or 2
[2-
DIGIT
REMOTE
CONTROL
#]
01 to 32; 00 = all remote controls.
Goes to next available PGM.
If PGM type is 3
[2-
DIGIT
ZONE
#]
01 to 32; 00 = all zones.
Goes to next available PGM.
If PGM type is 4
[1]
and/or
[2]
+
[
ENTER
]
If system is partitioned, select partition(s) and press [
ENTER
].
Goes to next available PGM.
Magellan / Spectra SP
5
Plik z chomika:
klamer87
Inne pliki z tego folderu:
pgm1_i.pdf
(730 KB)
6060_u.pdf
(4659 KB)
PCS100-IINS1.pdf
(1259 KB)