SPECIFIC VEHICLE ALARM FITTING INSTRUCTIONS REV. 00
www.cobra.it
CITROEN
MOD. XSARA 2 YEAR. 02
PETROL
DIESEL
X
MAKE
ALARM/SIREN
POSITION
Position the compact alarms and the sirens on the dome of the shock absorber,
passenger’s side.
CENTRAL UNIT POSITION
Position the modular systems and the modules under the dashboard, driver’s
side.
POWER SUPPLY
+ 30: connect to the 3 mm 2 RED wire located at the entrance of the fuse box.
- 31: connect with a cable terminal to one of the original ground wire located on
the right of the BSI operating central.
IGNITION WIRE
+ 15/54: connect to the wire, at the position nr. 16, coming out of the 26 way blue
connector of the BSI operating central.
DIRECTION INDICATORS
Connect to the wires at the positions nr.13 and nr.14 coming out of a 16 way black
connector of the BSI operating central.
ELECTRIC WINDOWS
Positive control signal
Front window, driver’s side:
refer to the diagram nr. 113.
Front window, passenger’s side:
refer to the diagram nr. 113.
Rear window, driver’s side:
cut the wire located at the position nr. 3, in the 16 way grey connector.
Rear window, passenger’s side:
cut the wire located at the position nr. 4, in the 16 way grey connector.
CENTRAL DOORS LOCKING Original door motor control signal
For antithefts of the Bridge serie, refer to the diagram nr.102 ; for antithefts of the
3100 serie refer to the diagram nr.102A .
IMMOBILISATION POINT 1
Fuel pump
Cut the YELLOW wire located in a wiring harness coming out of the connector of
the inertial switch placed on the shock absorber support, passenger’s side.
IMMOBILISATION POINT 2
General underlock
Cut the wire located at the position nr. 16 coming out of the 26 way blue
connector of the BSI central.
STARTER
+50: Cut the YELLOW wire located in a flying wiring harness placed on the rear
of the cover of the fuse box.
BONNET SWITCH
Install an additional switch on the front headlamp support plate, driver’s side.
DOORS SWITCH
Connect to the wire at the position nr. 23 of the 26 way blue connector of the BSI
operating central.
Note: the lamp control is with positive polarity.
Note: This information is not binding, therefore it must be considered only an example for installation purposes that must be executed
as per the instructions given on the product installation manual.
cixs202gbb.doc
108355093.011.png 108355093.012.png
SPECIFIC VEHICLE ALARM FITTING INSTRUCTIONS REV. 00
www.cobra.it
FITTING DIAGRAM N° 102
Diagram to make the lock and unlock of the doors on
Citroen XSARA 2 year 2002
(for Bridge serie antithefts)
VIOLET YELLOW/BLACK ORANGE GREY/BLACK VIOLET/ORANGE
+ 30
Position nr. 4
Position nr. 3
Towards door motors 16 way black connector
Note: This information is not binding, therefore it must be considered only an example for installation purposes that must be executed
as per the instructions given on the product installation manual.
cixs202gbb.doc
108355093.013.png 108355093.014.png 108355093.001.png 108355093.002.png
SPECIFIC VEHICLE ALARM FITTING INSTRUCTIONS REV. 00
www.cobra.it
FITTING DIAGRAM N°102A
Diagram to make the lock and unlock of the doors on
Citroen XSARA 2 year 2002
(for 3100 serie antithefts)
VIOLET YELLOW/BLACK ORANGE GREY/BLACK VIOLET/ORANGE
ORANGE/WHITE
+ 30
Position nr. 4
Position nr. 3
Towards door motors 16 way black connector
Note: This information is not binding, therefore it must be considered only an example for installation purposes that must be executed
as per the instructions given on the product installation manual.
cixs202gbb.doc
108355093.003.png 108355093.004.png 108355093.005.png
SPECIFIC VEHICLE ALARM FITTING INSTRUCTIONS REV. 00
www.cobra.it
FITTING DIAGRAM N° 113
Diagram for windows connection on
CITROEN XSARA 2 year 2002
Diagram for windows locking using the BROWN/WHITE wire of the autodriven Bridge serie antithefts.
Left Right
push botton push botton
1 2 3 4 5
+30 LIGHT BLUE GREY
Diode 1N4004
BROWN/WHITE Diode 1N4004
Diagram for windows locking using the BROWN wire of the no autodriven Bridge serie, 3100 e 3800 antithefts.
Left Right
push botton push botton
1 2 3 4 5 6 7
LIGHT BLUE GREY
+30
Diode 1N4004
BROWN Diode 1N4004
Note: This information is not binding, therefore it must be considered only an example for installation purposes that must be executed
as per the instructions given on the product installation manual.
cixs202gbb.doc
1052
1055
108355093.006.png 108355093.007.png 108355093.008.png 108355093.009.png 108355093.010.png