RF160C_BA_201005_en.pdf
(
2543 KB
)
Pobierz
___________________
1
RF160C communication module with
Introduction
FC 44
___________________
2
Description
___________________
3
Mounting
SIMATIC Sensors
___________________
4
Connecting
RFID systems
RF160C communication module
with FC 44
___________________
5
Parameterizing
___________________
6
Diagnostics
Operating Instructions
___________________
7
Service and maintenance
___________________
8
Technical data
___________________
9
Dimension drawings
___________________
10
Connecting cable
___________________
11
Ordering data
___________________
12
Service & Support
Programming of the RF160C
on PROFIBUS DP
___________________
A
___________________
B
Handshake control
05/2010
J31069-D0219-U001-A1-7618
Legal information
Warning notice system
This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent
damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert
symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are
graded according to the degree of danger.
Legal information
DANGER
indicates that death or severe personal injury will result if proper precautions are not taken.
WARNING
indicates that death or severe personal injury may result if proper precautions are not taken.
CAUTION
with a safety alert symbol, indicates that minor personal injury can result if proper precautions are not taken.
CAUTION
without a safety alert symbol, indicates that property damage can result if proper precautions are not taken.
NOTICE
indicates that an unintended result or situation can occur if the corresponding information is not taken into
account.
If more than one degree of danger is present, the warning notice representing the highest degree of danger will
be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to
property damage.
Qualified Personnel
The product/system described in this documentation may be operated only by personnel qualified for the specific
task in accordance with the relevant documentation for the specific task, in particular its warning notices and
safety instructions. Qualified personnel are those who, based on their training and experience, are capable of
identifying risks and avoiding potential hazards when working with these products/systems.
Proper use of Siemens products
Note the following:
WARNING
Siemens products may only be used for the applications described in the catalog and in the relevant technical
documentation. If products and components from other manufacturers are used, these must be recommended
or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and
maintenance are required to ensure that the products operate safely and without any problems. The permissible
ambient conditions must be adhered to. The information in the relevant documentation must be observed.
Trademarks
All names identified by ® are registered trademarks of the Siemens AG. The remaining trademarks in this
publication may be trademarks whose use by third parties for their own purposes could violate the rights of the
owner.
Disclaimer of Liability
We have reviewed the contents of this publication to ensure consistency with the hardware and software
described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the
information in this publication is reviewed regularly and any necessary corrections are included in subsequent
editions.
Siemens AG
Industry Sector
Postfach 48 48
90026 NÜRNBERG
GERMANY
J31069-D0219-U001-A1-7618
Ⓟ 05/2010
Copyright © Siemens AG 2010.
Technical data subject to change
Table of contents
1
Introduction
................................................................................................................................................
5
2
Description
.................................................................................................................................................
7
2.1
Area of application
.........................................................................................................................
7
2.2
Features
.........................................................................................................................................
8
2.3
Design
............................................................................................................................................
9
2.4
Potential
.......................................................................................................................................
10
2.5
System integration
.......................................................................................................................
11
3
Mounting
..................................................................................................................................................
13
3.1
Mounting position, mounting dimensions
.....................................................................................
13
3.2
Mounting the communication module
..........................................................................................
14
4
Connecting
..............................................................................................................................................
17
4.1
Setting the PROFIBUS address.
..................................................................................................
18
4.2
Wiring connection block ECOFAST
.............................................................................................
20
4.3
Wiring connection block M12, 7/8".
..............................................................................................
24
4.4
Loop-through connection of PROFIBUS DP and supply voltage
................................................
29
4.5
Connection of RF160C to protective ground (PE)
.......................................................................
30
5
Parameterizing
........................................................................................................................................
33
5.1
Configuration
................................................................................................................................
33
5.2
Parameter setting by means of GSD file
.....................................................................................
37
5.3
Description of the FC 44
..............................................................................................................
43
5.3.1
General
........................................................................................................................................
43
5.3.2
Block specification
.......................................................................................................................
43
5.3.2.1
Technical data
..............................................................................................................................
43
5.3.2.2
Communication between RF160C and FC 44
.............................................................................
44
5.3.2.3
Configuration scheme
..................................................................................................................
45
5.3.3
BEDB command data block
.........................................................................................................
46
5.3.3.1
General description of the BEDB
.................................................................................................
46
5.3.3.2
Structure of the BEDB
..................................................................................................................
46
5.3.3.3
Command and status word "BEST"
.............................................................................................
47
5.3.3.4
DATDB/DATDW data field indicator
............................................................................................
50
5.3.3.5
Error display word "ANZ"
.............................................................................................................
51
5.3.3.6
Table of possible commands
.......................................................................................................
52
5.3.3.7
Parameterization of the commands
.............................................................................................
52
5.3.3.8
Starting the commands
................................................................................................................
55
5.3.4
Processing data memories
..........................................................................................................
56
5.3.4.1
Address space of the data memory versions for MOBY D
..........................................................
56
5.3.4.2
Address space of the data memory versions for MOBY U
..........................................................
58
5.3.4.3
Address space of the data memory versions for RF300
.............................................................
59
5.3.4.4
Address space of the data memory versions for RF600
.............................................................
63
RF160C communication module with FC 44
Operating Instructions, 05/2010, J31069-D0219-U001-A1-7618
3
Table of contents
5.3.5
Application examples
..................................................................................................................
64
5.3.5.1
Structogram: FC 44 scanning by user
........................................................................................
64
5.3.5.2
Initialization of data memories
....................................................................................................
64
5.3.5.3
Parameterization examples
.........................................................................................................
65
5.3.6
Commissioning instructions for RF160C with FC 44
..................................................................
67
6
Diagnostics
..............................................................................................................................................
69
6.1
Diagnosis using LEDs
.................................................................................................................
69
6.2
Parameterization of the diagnostics
............................................................................................
73
6.3
Structure of the diagnostics frame
..............................................................................................
74
6.4
Evaluation of the error display ANZ (FC44)
................................................................................
75
6.4.1
FC 44 error messages: Right byte from ANZ (DBB7 in BEDB)
..................................................
75
6.4.2
Error messages of the RF160C or connected readers. Left byte from ANZ (DBB6 in
BEDB)
.........................................................................................................................................
76
7
Service and maintenance
........................................................................................................................
81
7.1
Firmware update
.........................................................................................................................
81
8
Technical data
.........................................................................................................................................
83
9
Dimension drawings
................................................................................................................................
87
9.1
Dimension drawings for RF160C with fixing holes
.....................................................................
87
10
Connecting cable
.....................................................................................................................................
89
10.1
Routing of standard cables
.........................................................................................................
89
10.2
Self-assembled cables
................................................................................................................
91
11
Ordering data
...........................................................................................................................................
93
12
Service & Support
....................................................................................................................................
95
A
Programming of the RF160C on PROFIBUS DP
.....................................................................................
97
A.1
Introduction
.................................................................................................................................
97
A.2
Structure of the command byte (byte 1 of the telegram)
............................................................
99
A.3
Commands
................................................................................................................................
100
B
Handshake control
.................................................................................................................................
103
B.1
Introduction
...............................................................................................................................
103
B.2
General handshake sequence
..................................................................................................
104
B.3
Telegram traffic for a command
................................................................................................
104
B.4
Signal timing for command and RESET command handshake
................................................
106
B.5
Cancellation of a running command
.........................................................................................
107
B.6
Programming example according to DIN IEC 61131
................................................................
108
RF160C communication module with FC 44
4
Operating Instructions, 05/2010, J31069-D0219-U001-A1-7618
1
Introduction
Purpose of these operating instructions
The information provided in these operating instructions will enable you to commission the
RF160C communication module on the PROFIBUS DP/DP-V0 as a DP slave.
Basic knowledge required
These operating instructions assume general knowledge of automation engineering and
identification systems.
Scope of the manual
The operating instructions apply to the RF160C communication module.
Position in the information landscape
● In addition to these operating instructions, you require the operating instructions for the
DP master used.
● The manual of the relevant SIMATIC identification system contains information on the
write/read devices to be connected.
Conventions
The following terms/abbreviations are used synonymously in this document:
● Reader, read/write device, SLG
● Tag, transponder, mobile data memory, data carrier, MDS
● Communication module, interface module, ASM
Registered trademarks
SIMATIC ® is a registered trademark of Siemens AG.
RF160C communication module with FC 44
Operating Instructions, 05/2010, J31069-D0219-U001-A1-7618
5
Plik z chomika:
Przechowalnia5
Inne pliki z tego folderu:
Kurs Programowania Step7 by Siemens.rar
(206348 KB)
sinamics s120 FH1.pdf
(8950 KB)
Siemens_S7300_Moduly_podrecznik_PL.pdf
(7881 KB)
Siemens_S7_300_Programowanie_STEP7_PL.pdf
(18657 KB)
Siemens S120 DE IH1.pdf
(2337 KB)
Inne foldery tego chomika:
DOKUMENTACJA
Programy
Przykłady
s7-200 Dokumenty
s7300
Zgłoś jeśli
naruszono regulamin