HEX BUFFER/CONVERTERS
HCC/HCF4009UB
HCC/HCF4010B
HEX BUFFER/CONVERTERS
. HIGH-TO-LOW LEVEL LOGIC CONVERSION
non-inverting Hex Buffer/Converters, respectively.
Both devices can be used as CMOS to TTL or DTL
logic-level converters, as current ”sink” or ”source”
drivers or as multiplexer (1 to 6).
4049UB and 4050B are prefered replacements for
4009UB and 4010B , respectively, in buffer applica-
tions.
. HIGH”SINK” AND ”SOURCE” CURRENT CA-
PABILITY
. 5V, 10V AND 15V PARAMETRIC RATINGS
. MAXIMUM INPUT CURRENT OF 100
. PACKAGE AND TEMPERATURE RANGE;
m
AAT
18V OVER FULL
. 100% TESTED FOR QUIESCENT CURRENT
AT 20V
100nA AT 18V AND 25 o C
. MEETS ALL REQUIREMENTS OF JEDEC TEN-
TATIVE STANDARD N. 13A, ” STANDARD
SPECIFICATIONS FOR DESCRIPTION OF B
SERIES CMOS DEVICES ”
EY
(Plastic Package)
F
(Ceramic Package)
DESCRIPTION
The HCC4009UB/4010B (extended temperature
range) and the HCF4009UB/4010B (intermediate
temperature range) are monolithic integrated cir-
cuits available in 16-lead dual in line plastic or ce-
ramic packages and plastic micropackage.
The HCC/HCF4009UB/4010B are inverting and
M1
(Micro Package)
C1
(Chip Carrier)
ORDER CODES :
HCCXXXXBF
HCFXXXXBM1
HCFXXXXBEY
HCFXXXXBC1
PIN CONNECTIONS
4009UB
4010B
September 1988
1/13
4009UB–INVERTING TYPE
4010B–NON INVERTING TYPE
. CMOS TO DTL/TTL HEX CONVERTER
. MULTIPLEXER: 1-TO-6 OR 6-TO-1
21708443.002.png
HCC/HCF4009UB HCC/HCF4010B
SCHEMATIC DIAGRAM: COS/MOS TO DTL OR TTL CONVERTER (1 of 6 identical units)
4009UB
4010B
Connect V CC to DTL or TTL supply and V DD to COS/MOS supply
ABSOLUTE MAXIMUM RATING
Symbol
Parameter
Value
Unit
V DD *
Supply Voltage: HCC Types
HCF Types
-0.5 to +20
-0.5 to +18
V
V
V i
Input Voltage
-0.5 to V DD + 0.5
V
I I
DC Input Current (any one input)
±
10
mA
P tot
Total Power Dissipation (per package)
Dissipation per Output Transistor
for Top = Full Package Temperature Range
200
mW
100
mW
T op
Operating Temperature: HCC Types
HCF Types
-55 to +125
-40 to +85
o C
o C
o C
Stresses above those listed under ”Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress ratingonly and functional
operation of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied. Exposure
to absolute maximum rating conditions for external periods may affect device reliability.
* All voltage values are referred to V SS pin voltage.
T stg
Storage Temperature
-65 to +150
RECOMMENDED OPERATING CONDITIONS
Symbol
Parameter
Value
Unit
V DD
Supply Voltage: HCC Types
HCF Types
3to18
3to15
V
V
V I
Input Voltage
0 to V DD
V
o
T op
Operating Temperature: HCC Types
HCF Types
-55 to +125
-40 to +85
C
o C
2/13
21708443.003.png
HCC/HCF4009UB HCC/HCF4010B
STATIC ELECTRICAL CHARACTERISTICS (over recommended operating conditions)
Test Conditios
Value
Symbol
Parameter
V I
(V)
V O
(V)
|I O |
V DD
(V)
T LOW * 25 o C T HIGH *
Min. Max. Min. Typ. Max. Min. Max.
Unit
(
m
A)
I L
Quiescent
Current
0/5
5
1
0.02
1
30
HCC
Types
0/10
10
2
0.02
2
60
0/15
15
4
0.02
4
120
m
A
0/20
20
20
0.04 20
600
HCF
Types
0/5
5
4
0.02
4
30
0/10
10
8
0.02
8
60
0/15
15
16
0.02 16
120
V OH
Output High
Voltage
0/5
5 4.95
4.95
4.95
V
0/10
10 9.95
9.95
9.95
0/15
15 14.95
14.95
14.95
V OL
Output Low
Voltage
5/0
5
0.05
0.05
0.05
10/0
10
0.05
0.05
0.05
V
15/0
15
0.05
0.05
0.05
V IH
Input High
Voltage (4009UB)
0.5
5
4
4
4
1
10
8
8
8
V
1.5
15 12.5
12.5
12.5
V IH
Input High
Voltage (4010B)
4.5
5
3.5
3.5
3.5
9
10
7
7
7
V
13.5
15
11
11
11
V IL
Input Low
Voltage (4009UB)
4.5
5
1
1
1
V
9
10
2
2
2
13.5
15
2.5
2.5
2.5
V IL
Input Low
Voltage (4010B)
0.5
5
1.5
1.5
1.5
V
1
10
3
3
3
1.5
15
4
4
4
I OH
Output
Drive
Current
0/5
2.5
5
-1
-0.8 -1.6
-0.58
HCC
Types
0/5
4.6
5 -0.25
-0.2 -0.4
-0.15
0/10
9.5
10 -0.55
-0.45 -0.9
-0.33
0/15 13.5
15 -1.65
-1.5
-3
-1.1
mA
0/5
2.5
5
-0.9
-0.8 -1.6
-0.65
HCF
Types
0/5
4.6
5 -0.23
-0.2 -0.4
-0.18
0/10
9.5
10 -0.5
-0.45 -0.9
-0.38
0/15 13.5
15 -1.6
-1.5
-3
-1.25
I OL
Output
Sink
Current
HCC
Types
0/5
0.4
5 3.75
3
4
2.1
0/10
0.5
10
10
8
10
5.6
0/15
1.5
15
30
24
36
16
mA
HCF
Types
0/5
0.4
5
3.6
3
4
2.4
0/10
0.5
10 0.96
8
10
6.4
0/15
1.5
15
40
24
36
1.9
I IH , IL
Input Leakage
Current
0/18
18
±
0.1
±
10 -5
±
0.1
±
m
A
C I
Input
Capacitance
4009UB
Any Input
15 22.6
4010B
5
7.5
pF
*T LOW =-55 o Cfor HCC device: -40 o C for HCF device.
*T HIGH =+125 o Cfor HCC device: +85 o C for HCF device.
The Noise Margin for both ”1” and ”0” level is: 1V min. with V DD = 5 V, 2 V min. with V DD = 10 V, 2.5 V min. with V DD =15V
3/13
1
21708443.004.png
HCC/HCF4009UB HCC/HCF4010B
,
typical temperature coefficent for all V DD values is 03 %/ o C, all input rise and fall times= 20 ns)
W
Symbol
Parameter
Test Conditions
Value
Unit
V DD (V) V I (V) V CC (V) Min. Typ. Max.
t PLH
Propagation Delay Time
(4009UB)
5
5
5
70
140
10
10
10
40
80
ns
10
10
5
35
70
15
15
15
30
60
15
15
5
30
60
t PLH
Propagation Delay Time
(4010B)
5
5
5
100
200
10
10
10
50
100
ns
10
10
5
50
100
15
15
15
35
70
15
15
5
35
70
t PHL
Propagation Delay Time
(4009UB)
5
5
5
30
60
10
10
10
20
40
ns
10
10
5
15
30
15
15
15
15
30
15
15
5
10
20
t PHL
Propagation Delay Time
(4010B)
5
5
5
65
130
10
10
10
35
70
ns
10
10
5
30
70
15
15
15
25
50
15
15
5
20
40
t TLH
Transition Time
5
5
5
150
350
10
10
10
75
150
ns
15
15
15
55
110
t THL
Transition Time
5
5
5
35
70
10
10
10
20
40
ns
15
15
15
15
30
Minimum and Maximum Voltage Transfer Char-
acteristics for 4009UB
Typical Voltage Transfer Characteristics As a
Function of Temperature for 4009UB
4/13
DYNAMIC ELECTRICAL CHARACTERISTICS (T amb =25 o C, C L =50pF,R L = 200 K
21708443.005.png
HCC/HCF4009UB HCC/HCF4010B
Minimum and Maximum Voltage Transfer Char-
acteristics for 4010B
Minimum and Maximum Voltage Transfer Char-
acteristics for 4010B
Minimum and Maximum Voltage Transfer Char-
acteristics for 4010B
Typical Voltage Transfer Characteristics As a
Function ot Temperature for 4010B
Typical Output Los (sink) Current Characteristics
Minimum output Low (sink) Current Charac-
teristics
5/13
21708443.001.png