SINAUT_MD720-3.pdf
(
924 KB
)
Pobierz
Microsoft Word - MN_SINAUT-MD720-3_76.doc
SIMATIC NET
Preface, Contents
GPRS/GSM-Modem
SINAUT MD720-3
Introduction
1
System manual
Inserting the SIM card
2
Connecting the device and
switching on the device
3
SINAUT MD720-3 in Terminal
Mode
4
SINAUT MD720-3 in OPC Mode
5
Service function
6
Technical Data
7
Glossary
C79000-G8976-C211
Release 02/2006
Safety Guidelines
This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent
damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert
symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are
graded according to the degree of danger.
!
Danger
indicates that death or severe personal injury will result if proper precautions are not taken.
!
Warning
indicates that death or severe personal injury may result if proper precautions are not taken.
!
Caution
with a safety alert symbol, indicates that minor personal injury can result if proper precautions are not taken.
Caution
without a safety alert symbol, indicates that property damage can result if proper precautions are not taken.
Notice
indicates that an unintended result or situation can occur if the corresponding information is not taken into
account.
If more than one degree of danger is present, the warning notice representing the highest degree of danger will
be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to
property damage.
Qualified Personnel
The device/system may only be set up and used in conjunction with this documentation. Commissioning and
operation of a device/system may only be performed by qualified personnel. Within the context of the safety notes
in this documentation qualified persons are defined as persons who are authorized to commission, ground and
label devices, systems and circuits in accordance with established safety practices and standards.
Prescribed Usage
Note the following:
!
Warning
This device may only be used for the applications described in the catalog or the technical description and only in
connection with devices or components from other manufacturers which have been approved or recommended
by Siemens. Correct, reliable operation of the product requires proper transport, storage, positioning and
assembly as well as careful operation and maintenance.
Trademarks
All names identified by ® are registered trademarks of the Siemens AG. The remaining trademarks in this
publication may be trademarks whose use by third parties for their own purposes could violate the rights of the
owner.
Disclaimer of Liability
We have reviewed the contents of this publication to ensure consistency with the hardware and software
described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the
information in this publication is reviewed regularly and any necessary corrections are included in subsequent
editions.
Siemens AG
Automation and Drives
Postfach 48 48
90437 NÜRNBERG
DEUTSCHLAND
Order No.:
C79000-G8976-C211
Release 02/2006
Copyright © Siemens AG 2006
Technical data subject to change
2
General
The product SINAUT MD720-3 complies with European standard EN60950, 05.2003,
Safety of Information Technology Equipment.
Read the installation instructions carefully before using the device.
Keep the device away from children, especially small children.
The device must not be installed or operated outdoors or at damp locations.
Do not operate the device if the connecting leads or the device itself are damaged.
External power supply
Use only an external power supply which also complies with EN60950. The output
voltage of the external power supply must not exceed 30VDC. The output of the
external power supply must be short-circuit proof.
!
Warning
The power supply unit to supply the SINAUT MD720-3 must comply with NEC Class 2
circuits as outlined in the National Electrical Code (ANSI/NFPA 70) only.
When connecting to a battery or accumulator, make sure that an all-pole circuit-
breaker (main battery switch) with sufficient selectivity and a fuse with sufficient
selectivity are provided between the device and the battery or accumulator.
Please pay regard to section
7
Technical Data
of the system manual, as well as the
installation and utilisation regulations of the respective manufacturers of the power
supply, the battery or the accumulator.
SIM card
To install the SIM card the device must be opened. Before opening the device,
disconnect it from the supply voltage. Static charges can damage the device when it is
open. Discharge the electric static of your body before opening the device. To do so,
touch an earthed surface, e.g. the metal casing of the switch cabinet. Please pay
regard to section
2
Inserting the SIM card
o
f this system manual.
Handling cables
Never pull a cable connector out of a socket by its cable, but pull on the connector
itself. Cable connectors with screw fasteners (D-Sub) must always be screwed on
tightly. Do not lay the cable over sharp corners and edges without edge protection. If
necessary, provide sufficient strain relief for the cables.
For safety reasons, make sure that the bending radius of the cables is observed.
SINAUT MD720-3
C79000-G8976-C211
3
Failure to observe the bending radius of the antenna cable results in the deterioration
of the system's transmission and reception properties. The minimum bending radius
static must not fall below 5 times the cable diameter and dynamic below 15 times the
cable diameter.
Radio device
!
Warning
Never use the device in places where the operation of radio devices is prohibited. The
device contains a radio transmitter which could in certain circumstances impair the
functionality of electronic medical devices such as hearing aids or pacemakers. You
can obtain advice from your physician or the manufacturer of such devices. To
prevent data carriers from being demagnetised, do not keep disks, credit cards or
other magnetic data carriers near the device.
Installing antennas
!
Warning
The emission limits as recommended by the Commission on Radiological Protection
(13/14 September 2001) must be observed.
Installing an external antenna
Caution
When installing an antenna outdoors it is essential that the antenna is fitted correctly
by a qualified person. Lightning Protection Standard VDE V 0185 Sections 1 to 4, in
its current version, and further standards must be observed.
Lightning protection category for buildings
Caution
For outdoor installation, the antenna may be fitted only within the lightning protection
zones O/E or 1. These lightning protection zones are prescribed by the lightning
protection spherical radius.
SINAUT MD720-3
4
C79000-G8976-C211
The EMV lightning protection zone concept
Caution
The EMV lightning protection zone concept is to be observed. To avoid large induction
loops a lightning protection equipotential bonding is to be used. If the antenna or
antenna cable is installed near to the lightning protection system, the minimum
distances to the lightning protection system must be observed. If this is not possible,
insulated installation as described in VDE V 0185 Sections 1 to 4, in its current
version, is essential.
FCC Part 15
This equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful interference
to radio communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
•
Reorient or relocate the receiving antenna.
•
Increase the separation between the equipment and receiver.
•
Connect the equipment into an outlet on a circuit different from that to which
the receiver is connected.
•
Consult the dealer / installer or an experienced radio/TV technician for help.
FCC Part 15.19
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions:
1. this device may not cause harmful interference, and
2. this device must accept any interference received, including interference that
may cause undesired operation.
SINAUT MD720-3
C79000-G8976-C211
5
Plik z chomika:
hantajo
Inne pliki z tego folderu:
TP070.pdf
(394 KB)
Teleservice_MD720_3_en.pdf
(1152 KB)
TD200_TD200C_TD100C.pdf
(2611 KB)
TC35_AT_Command_Set.pdf
(2027 KB)
TC35.pdf
(741 KB)
Inne foldery tego chomika:
fatek automotion corp
Logo!
Mitsubishi
Omron
S7-300
Zgłoś jeśli
naruszono regulamin