TECHNICAL MANUAL
OPERATOR'S, ORGANIZATIONAL,
DIRECT SUPPORT AND GENERAL
SUPPORT MAINTENANCE MANUAL
FOR
PULSE GENERATOR AN/USM-359A
(NSN 6625-01-077-4620)
(TEKTRONIX MODEL PG 508 WITH TM 503)
HEADQUARTERS, DEPARTMENT OF THE ARMY
27 MARCH 1981
 
TM 11-6625-2980-14
SAFETY SUMMARY
This manual contains safety information which the user must follow to ensure safe operation of this instrument.
WARNING information is intended to protect the operator; CAUTION information is intended to protect the instrument.
The following general safety precautions must be observed during all phases of operation, service, and repair of this
instrument. Failure to comply with these precautions or with specific warnings elsewhere in this manual violates safety
standards of design, manufacture, and intended use of the instrument.
Warning statements precede potentially dangerous procedures throughout this manual. The instructions contained in
the warnings must be followed. The following warning statements are found in this manual.
WARNING
Use a proper power source. This instrument is designed to operate from a power source with its neutral
at or near ground potential with a separate safety-earth conductor. It is not intended for operation from
two phases of a multi-phase system, or across the legs of a single-phase, three-wire system.
WARNING
Avoid live circuits. Dangerous voltages exist at several points throughout this instrument. When the
instrument is operated with the cover removed, do not touch exposed connections or components. Some
transistors have voltages present on their cases. Disconnect power before cleaning the instrument or
replacing parts.
WARNING
Avoid contact with chemicals. Handle silicone grease with care. Avoid getting silicon-in grease in
eyes. Wash hands thoroughly after use.
WARNING
Adequate ventilation should be provided while using TRICHLOROTRIFLUOROETHANE. Prolonged
breathing of vapor should be avoided. The solvent should not be used near heat or open flames; the
products of decomposition are toxic and irritating. Since TRICHLOROTRIFLUOROETHANE dissolves
natural oils, prolonged contact wit h skin should be avoided. When necessary,-use gloves which the
solvent cannot penetrate. If the solvent is taken internally, consult a-physician immediately.
Compressed air is dangerous and can cause serious bodily harm if protective means or methods are not
observed to prevent a chip or particle (of whatever size) from being blown into the eyes or unbroken skin
of the operator or other personnel. Compressed air shall not be used for cleaning purposes except where
reduced to less than 30 p.s.i.f. and then only with effective chip guarding and personnel protective
equipment. Do not use compressed air to dry parts when Trichlorotrifloroethane has been used.
CAUTION
Avoid power surge damage. Do not remove or install plug-in unit while power is on as damage may
occur to circuitry.
434143688.003.png
TM 11-6625-2980-14
This manual contains copyright material reproduced b)y permission of Tektronix. Inc.
TECHNICAL MANUAL
HEADQUARTERS
DEPARTMENT OF THE ARMY
No. 11-6625-2980-14
WASHINGTON, DC, 27 March 1981
OPERATOR'S, ORGANIZATIONAL, DIRECT SUPPORT, AND
GENERAL SUPPORT MAINTENANCE MANUAL
FOR
GENERATOR, PULSE AN/USM-359A
(TEKTRONIX MODEL PG 508 WITH TM 503)
(NSN 6625-01-077-4620)
REPORTING ERRORS AND RECOMMENDING IMPROVEMENTS
You can help improve this manual. If you find any mistakes or if you know of a way to
improve the procedures, please let us know. Mail your letter, DA Form 2028 (Recommended
Changes to Publications and Blank Forms), or DA Form 2028-2 located in back of this
manual direct to: Commander, US Army Communications and Electronics Materiel
Readiness Command, ATTN: DRSEL-ME-MQ, Fort Monmouth, New Jersey 07703.
This manual is an authentication of the manufacturer's commercial literature which, through usage, has been found to
cover the data required to operate and maintain this equipment. Since the manual was not prepared in accordance with
military specifications, the format has not been structured to consider levels of maintenance.
 
TM 11-6625-2980-14
TABLE OF CONTENTS
Page
Page
Section 0
INTRODUCTION
0-1
APPENDIX A TM 503 MAINFRAME
INSTALLATION PROCEDURE A-1
SECTION 1 OPERATING INSTRUCTIONS
Instrument Description
1-1
Section II. TM 503 OPERATING
I NSTRUCTIONS
A-3
Installation and Removal
1-1
Introduction
A-3
BASIC OPERATION
1-2
Powering Up
A-3
Period and Duration Selection
1-2
Building a System
A-5
Duty Factors
1-2
Specifications
A-6
Delayed and Paired Pulse Selection 1-2
Transition Time Selection
1-3
Section III. TM 503 SYSTEM MAINTENANCE
A-7
Transition Time Selection
1-3
General
A-7
External Triggering and Gating
1-3
Troubleshooting Aids
A-8
Trigger Output
1-4
Troubleshooting Techniques
A-8
Manual Trigger
1-4
Parts Replacement
A-10
Control Error Light
1-4
Diagrams and Circuit Board
Control Error Light
1-4
Illustrations
A-14
OPERATING CONSIDERATIONS 1-4
Power Module Interface Pin
Output Termination’s and
Assignments
A-15
Connections
1-4
Detailed Block Diagram
A-16
Connections
1-4
Parts Location Grid
A- 17
Rise Time Measurements in Linear
Parts Location Grid
A-17
Systems
1-5
Replaceable Mechanical Parts
A-19
Counted Burst Using the DD 501
APPENDIX BR EFERENCES
External Voltage Control 1-5
Digital Delay Unit 1-5
Definitions of Pulse Characteristics 1-8
APPENDIX C COMPONENTS OF END ITEM AND
SPECIFICATIONS
1-9
BASIC ISSUE ITEMS LIST
Environmental Requirements
Section I.
INTRODUCTION
C-1
Using the Rear Interface
Scope
C-1
Connectors
General
C-1
Explanation of Columns
C-1
SECTION 2 THEORY OF OPERATION
Introduction
2-1
Section II. COMPONENTS OF END ITEM
C-2
Input Circuitry
2-1
Section III. BASIC ISSUE ITEMS
C-3
~ TRIG'D/GATED Light Circuitry
2-1
Triggered Mode
2-1
APPENDIX DADDITIONAL AUTHORIZATION
Period Generator
2-2
LIST (Not Applicable)
Delay Generator
2-2
Duration Generator
2-2
APPENDIX E MAINTENANCE ALLOCATION
Duration and Delay Control Error
Section I.
INTRODUCTION
E-1
Light Circuitry
2-3
General
E-1
Variable Transition Time Circuitry 2-3
Maintenance Function
E-1
Transition Time Control Error
Column Entries
E-2
Light Circuitry
2-3
Tool and Test Equipment
Level Control Multiplier
2-5
Requirement
E-2
Output Amplifier
2-6
Power Supply
2-6
Remarks
E-2
Section II. MAINTENANCE ALLOCATION
SECTION 3 SERVICE INFORMATION
CHART OR PULSE
Symbols and Reference Designator s3-1
GENERATOR AN/USM-359A
E-3
General Maintenance and
Section III. TOOL AND TEST EQUIPMENT
Adjustments
3-2
REQUIREMENTS FOR PULSE
Maintenance
3-2
GENERATOR AN/USM-359A
E-5
Circuit Board Removal
3-2
Circuit Board Removal
3-2
APPENDIX FE XPENDABLE SUPPLIES AND
Test Equipment
3-2
MATERIALS LIST
General
3-2
Section I.
INTRODUCTION
F-1
SECTION 4 CONTROLS AND CONNECTORS
Scope
F-1
AND SCHEMATIC DIAGRAMS
4-1
Explanation of Columns
F-1
SECTION 5 REPLACEABLE MECHANICAL
Section II. EXPENDABLE SUPPLIES AND
PARTS LIST
5-1
MATERIALS
F-2
iii
434143688.004.png 434143688.001.png
TM 11-6625-2980-14
LIST OF ILLUSTRATIONS
F ig.
Page
Page
No.
No.
No.
1-0
Pulse Generator AN/USM-359A.
vi
FO-1 Controls and connectors.
4-1
1-1 PG 508 installation and removal.
1-1
FO-2 Block diagram.
4-3
1-2 Locations of period, delay and duration
FO-3 Input circuit schematic diagram.
4-5
custom timing capacitors and TRIG/GATE
FO-4 Period generator schematic diagram.
4-7
input impedance switch.
1-2
FO-5 Delay generator schematic diagram.
4-9
1-3 Location for transition custom timing
FO-6 Duration generator and control error circuit
capacitor.
1-3
schematic diagram.
4-11
1-4 Equivalent circuit of external input for output
FO-7 Transition time generator schematic diagram.
4-13
voltage control.
1-5
FO-8 Level control multiplier schematic diagram .4-15
1-5 Location of trigger jumpers in DD 501 for
FO-9 Output amplifier schematic diagram.
4-17
selecting trigger or delay interval output
1-6
FO-10 Tracking voltage supply schematic diagram.
4-19
1-6 PG 508-DD 502 interconnections for counted
FO-11 PG 508 power supply schematic diagram.
4-21
burst operation.1-6
FO-12 TM 503 power supply schematic diagram.
4-23
1-7 Typical propagation delays using PG 508 with
5-1
Al board component locations.
5-2
DD 501 in counted burst mode at 50 MHz
FO-13 A2 board component locations.
5-3
repetition rate.
1-7
FO-14 A3 board component locations.
5-5
1-8 Pulse characteristics.
1-8
FO-15 A4 board component locations.
5-7
1-9 Locations for user installed rear interface
FO-16 PG 508 exploded view.
5-9
connections.
1-12
2-1 Simplified schematic for
control error indicator
logic with control settings
causing illumination.
2-4
iv
434143688.002.png
Zgłoś jeśli naruszono regulamin