VQ4000.tech.pdf

(2734 KB) Pobierz
13768148 UNPDF
Series VQ4000
Base Mounted Valve
Plug-in, Plug Lead/Single Unit
Model
(1) Response time ms (2)
(3)
Series
Configuration
Model
Effective area
(mm 2 ) (Cv)
Standard:
1W
Low wattage
and AC
Weight
(kg)
Single
Metal seal
Rubber seal
Metal seal
Rubber seal
Metal seal
Rubber seal
Metal seal
Rubber seal
Metal seal
Rubber seal
Metal seal
Rubber seal
VQ41 0
VQ41 1
VQ42 0
VQ42 1
VQ43 0
VQ43 1
VQ44 0
VQ44 1
VQ45 0
VQ45 1
VQ46 0
VQ46 1
5
5
0
5
0
5
5
5
0
5
0
5
5
5
36.0 (2.0)
39.6 (2.2)
36.0 (2.0)
39.6 (2.2)
32.4 (1.8)
36.0 (2.0)
36.0 (2.0)
39.6 (2.2)
36.0 (2.0)
39.6 (2.2)
19.8 (1.1)
21.6 (1.2)
20 or less
25 or less
12 or less
15 or less
45 or less
50 or less
45 or less
50 or less
45 or less
50 or less
55 or less
62 or less
22 or less
27 or less
12 or less
15 or less
47 or less
52 or less
47 or less
52 or less
47 or less
52 or less
57 or less
64 or less
0.23
(0.29)
Plug-in
Double
0.26
(0.32)
VQ4000
Closed
center
0.28
(0.34)
Exhaust
center
0.28
(0.34)
Pressure
center
0.28
(0.34)
Double
check
5
5
0.50
(0.56)
Plug lead
Note 1)
Note 2)
Value for valve on sub-plate and cylinder port Rc3/8
As per JISB8375-1981 (Supply pressure: 0.5MPa, with indicator light and surge
suppressor, clean air).
( ): Weight of plug lead unit
Table: Without sub-plate
With sub-plate: Add 0.41kgf for plug-in style, 0.30kgf for plug lead style.
Note 3)
Standard Specifications
Seal
Fluid
Max. operating pressure
Metal seal
Air, Inert gas
Rubber seal
Air, Inert gas
Symbol
(3)
1.0MPa
2 position single
3 position double check
Min. operating
pressure
Single
Double
3 position
0.15MPa
0.15MPa
0.15MPa
–10 to 50˚C
0.20MPa
0.15MPa
0.20MPa
–5 to 50˚C
(A)
4
(B)
2
(A)
4
(B)
2
5
(R1)
3
(R2)
Ambient and fluid temperature
Lubrication
Manual override
Shock/Vibration resistance
Enclosure
Coil rated voltage
Allowable voltage
Coil insulation
(1)
(1)
5
(R1)
3
(R2)
Not required
Non-locking push style/Locking slotted style (Option)
150/30 m/s 2
Dust proof (Available IP65 style)
12, 24V DCand100, 110, 200, 220V AC (50/60Hz)
±
2 position double (Metal)
(A)
4
(B)
2
(2)
5
(R1)
3
(R2)
2 position double (Rubber)
10% of rated voltage
Class B or equivalent
1W DC (42mA), 0.5W DC (21mA)
1W DC (83mA), 0.5W DC (42mA)
Inrush 1.2VA (12mA), Holding 1.2VA (12mA)
Inrush 1.3VA (11.7mA), Holding 1.3VA (11.7mA)
Inrush 2.4VA (12mA), Holding 2.4VA (12mA)
Inrush 2.6VA (11.7mA), Holding 2.6VA (11.7mA)
(A)
4
(B)
2
5
(R1)
3
(R2)
24V DC
12V DC
100V AC
110V AC
200V AC
220V AC
(3)
(3)
Power cnsumption
(Curent value)
3 position closed center
(A)
4
(B)
2
5
(R1)
3
(R2)
Note 1) Use dry air to prevent condensation when operating at low temperatures.
Note 2)
3 position exhaust center
(A)
4
(B)
2
Shock resistance:
No malfunction resulted from the impact test using a drop impact
tester. The test was performed on the axis and right angle direction
of the main valve and armature, for both energized and de-energized
states. (Value in the initial stage.)
No malfunction occurred in a one-sweep test between 8.3 and
2,000 Hz. Test was performed at both energize and de-energized
states to the axis and right angle direction of the main valve and
armature. (Value in the initial stage.)
5
(R1)
3
(R2)
Vibration resistance:
3 position pressure center
(A)
4
(B)
2
Note 3) Values in case of low power consumption model (0.5W).
5
(R1)
3
(R2)
1.11-4
1
(P)
1
(P)
1
(P)
1
(P)
1
(P)
1
(P)
1
(P)
13768148.154.png 13768148.162.png 13768148.173.png 13768148.183.png 13768148.001.png 13768148.012.png 13768148.023.png
Base Mounted
Single Unit Series VQ4000
How to Order Valve
Body style
O: Plug-in
Sub-plate
Port size
Without sub-plate
(for manifold)
Piping
Side piping
Bottom piping
02
03
Rc1/4
Rc3/8
B
Note) Refer to p.1.11-46
for thread standard.
SY
VQ4
1
0
0
SYJ
Plug-in
SX
Plug lead
VQ4
2
5
1
VK
Configuration
Enclosure
VZ
2 position single
3 position closed center
Dust-proof
Dust tight, jet proof
(Applicable to IP 65)
(A)
4 (B)
2
(A)
4 (B)
2
VF
1
3
W
5
(R1)
3
(R2)
5
(R1)
3
(R2)
VFR
2 position double
3 position exhaust center
Manual override
(A)
4
(B)
2
(A)
4
(B)
2
: Non-locking push style
B: Locking slotted style
VP7
4
5
(R1)
3
(R2)
5
(R1)
3
(R2)
VP4
2
2 position double
3 position pressure center
(A)
4 (B)
2
(A)
4
(B)
2
5
5
(R1)
3
(R2)
5
(R1)
3
(R2)
VQ
3 position double check
6 Note)
(A)
4
(B)
2
Light and surge voltage suppressor
VQ4
5
(R1)
3
(R2)
With
W/o light/With surge suppressor
VQZ
Note) Refer to p.1.11-36
for double check
style.
E
Electrical entry
VQD
Body style
Coil voltage
G
Lead wire
length 0.6m
VZS
5: Plug lead
Sub-plate
1
2
3
4
5
6
100V AC (50/60Hz)
200V AC (50/60Hz)
110V AC (50/60Hz)
220V AC (50/60Hz)
24V DC
12V DC
VFS
H
VS
Lead wire
lenghth 1.5m
VS7
Function
Standard (1W)
Low wattage (0.5W)
External pilot
Seal
Y
R
(1)
(2)
0
1
Metal seal
Rubber seal
Note 1)
Applicable to DC
specification.
Refer to p1.11-46 for
external pilot specification.
Combination of external
pilot and perfect interface is
not possible.
When specifying more than
one option, indicate
symbols alphabetically.
How to Order Sub-plate
Note 2)
VQ4000
Note 3)
Electrical entry
Port size
02
03
P
S
Plug-in conduit terminal
Plug lead
Rc1/4
Rc3/8
Piping
Side piping
Bottom piping
B
Note 1)
Bottom piping type is
applicable to only Rc1/4.
Refer to p.1.11-46
for thread standard.
Enclosure
How to replace pilot valve ass'y (Voltage)
W
Dust proof
Dust tight, Jet proof
Note 2)
V
Refer to p.1.11-42 and p.1.11-43
for part no. of pilot valve ass'y
Refer to p.1.11-3 for “How to
Replace”.
V
1.11-5
1
(P)
1
(P)
1
(P)
1
(P)
1
(P)
1
(P)
1
(P)
13768148.034.png 13768148.045.png
 
13768148.066.png
 
13768148.087.png 13768148.096.png 13768148.102.png 13768148.110.png 13768148.117.png 13768148.118.png 13768148.119.png 13768148.120.png 13768148.121.png 13768148.122.png 13768148.123.png 13768148.124.png 13768148.125.png 13768148.126.png 13768148.127.png 13768148.128.png 13768148.129.png 13768148.130.png 13768148.131.png 13768148.132.png 13768148.133.png 13768148.134.png 13768148.135.png 13768148.136.png 13768148.137.png 13768148.138.png 13768148.139.png 13768148.140.png 13768148.141.png 13768148.142.png 13768148.143.png 13768148.144.png 13768148.145.png 13768148.146.png 13768148.147.png 13768148.148.png 13768148.149.png 13768148.150.png 13768148.151.png
Series VQ4000
Base Mounted
Plug-in Manifold
How to Order Manifold
VV5Q
4
1
08
C8 F U1
K
Option
Series
Symbol
Option
4
VQ4000
None
Exhaust cleaner: For D side mounting
Exhaust cleaner: For U side mounting
Special wiring specification (Other than double wiring)
Name plate (T kit only)
Built-in silencer (Direct exhaust from both sides) F/L kits only
Built-in silencer (Direct exhaust from D side)
Built-in silencer (Direct exhaust from U side)
Enclosure IP65 (except F kit)
CD
CU
K
N
SB
SD
SU
W
(2)
Kit
(2, 3)
(4)
Manifold
Control unit
Refer to p.1.11-38
to p.1.11-41
1
Plug-in unit
Stations
02
2 stations
Note 1) When specifying more than one option, combine symbols
in alphabetical order. Example)-CDK
Note 2) Combination of [C ] and [S ] is not possible.
Note 3) Combination of T and S kit is not available.
Note 4) Specify the wiring specifications by means of the manifold
specification form. (except L kit)
Max. and Min. number
of stations depends on kit.
(Refer to table below.)
U
D
U
D
Kit/Electrical entry/Cable length
F
Port size
Kit
(D-sub connector)
T
Kit
(Terminal box kit)
C8
C10
C12
02
03
B
CM
One-touch fitting for ø8
One-touch fitting for ø10
One-touch fitting for ø12
Rc1/4
Rc3/8
Bottom piping Rc1/4
Mixed size
Electrical entry
D side U side
Indicator light
Kit
F
D0
D1
D2
D3
Kit
F
U0
U1
U2
U3
Without cable
Cable length 1.5m
Cable length 3m
Cable length 5m
2 to 16
stations
Applicable to IP65
Manual override
Kit T 0
Terminal box
3 to 18 stations
External pilot
supply port
L
Kit
(Lead wire kit)
S
Kit
(Serial interface kit)
The valve is equipped
with a lamp/surge
suppressor, and the
voltage is 24V DC.
Type of
connection
R1 port
A, B port
Applicable to IP65
*
P port
Applicable to INPUT
and OUTPUT styles.
R2 port
Electrical entry
D side U side
O
A
B
Without SI unit
With general SI unit
Applicable to IP65
Note) Shown VV5Q41-05C12FD0
Kit
L
D0
D1
D2
Kit
L
U0
U1
U2
Cable length 0.6m
Cable length 1.5m
Cable length 3m
2 to 16
stations
SI for MELSECNET/MINI-S3 Data Link System
(Mitsubishi Electric)
BB
SI for MELSECNET/MINI-S3 Data Link System
(2 power supply systems)(Mitsubishi Electric)
SI for SYSBUS Wire System (OMRON)
SI for Satellite I/O Link System (Sharp)
SI for 16 point Uni-wire System (NKE)
SI for 16 point S-LINK System (Sunx)
SI for 8 point S-LINK System (Sunx)
SI for T-LINK Mini System (Fuji Electric)
SI for Device Net and Compo Bus/D (OMRON)
SI for 16 point Compo Bus/S (OMRON)
SI for 8 point Compo Bus/S (OMRON)
SI for MELSECNET/MINI/S3 Data Link System (Mitsubishi Electric)
Input units (
Kit
S
C
D
F1
J1
J2
K
Q
R1
R2
BM
l
l
: 0 to 2 stations)
1.11-8
* Refer to p.1.11-26 to p.1.11-29 for INPUT and
OUTPUT styles.
13768148.152.png 13768148.153.png
 
13768148.155.png
 
13768148.156.png
 
13768148.157.png
 
13768148.158.png 13768148.159.png 13768148.160.png 13768148.161.png 13768148.163.png 13768148.164.png 13768148.165.png 13768148.166.png 13768148.167.png 13768148.168.png 13768148.169.png 13768148.170.png 13768148.171.png 13768148.172.png 13768148.174.png 13768148.175.png 13768148.176.png 13768148.177.png 13768148.178.png 13768148.179.png 13768148.180.png
Base Mounted
Plug-in Manifold Series VQ4000
Manifold Specifications
Series
Base No.
Connection
Por t
location
Por ting specifications
Por t size
(1)
Applicable max
stat ions
Applicable
valve
Weight 5 stations
(kg)
P, R
A, B
Rc1/2
C8 (For ø8)
C10 (For ø10)
C12 (For ø12)
Rc1/4
Rc3/8
F, T ki t
12 stations
2.24
W F kit-D-sub connector
W T kit-Terminal box
W L kit-Lead wire
W S kit-Serial transmission
Side
Option
l 00
L ki t
16 stations
VQ4
· L ki t
· Except solenoid
valve weight
VQ4000
VV5Q41–
lll
VQ4
l 01
Built-in silencer
(Direct exhaust)
SY
S ki t
10 stations
Bottom
Rc1/4
SYJ
Note 1) Refer to P.1.11-46 for further information on One-touch fit tings for inch sizes and thread standards.
SX
Number of Manifold Stations/Effective Area (mm 2 (Cv)) at Individual Operation
Model
2 position metal seal
VQ4 00
2 position rubber seal
VQ4 01
VK
Passage/Stations
P R A or B
A R R1, B R R2
P R A or B
A R R1, B R R2
1 station
28.8 (1.6)
32.4 (1.8)
36.0 (2.0)
37.8 (2.1)
5 stations
28.8 (1.6)
32.4 (1.8)
36.0 (2.0)
37.8 (2.1)
10 stations
28.8 (1.6)
32.4 (1.8)
36.0 (2.0)
37.8 (2.1)
15 stations
28.8 (1.6)
32.4 (1.8)
36.0 (2.0)
37.8 (2.1)
VZ
1
2
VF
1
2
VFR
Note) Port size. Rc3/8
VP7
Manifold Options
VP4
Blank plate assembly
VVQ4000–10A–1
Individual SUP spacer
VVQ4000–P–1–03
Individual EXH spacer
VVQ4000–R–1–03
V Refer to p.1.11-34 to p.1.11-37
for detail dimensions of each option.
V Refer to p.1.11-45 for spare parts no.
V Refer to p.1.11-38 to p.1.11-41
for control unit.
VQ
VQ4
VQZ
VQD
VZS
Interface speed control
VVQ4000–20A–1
SUP stop valve spacer
VVQ4000–37A–1
SUP EXH block plate
VVQ4000–16A
VFS
VS
VS7
<EXH block plate>
<SUP block plate>
Release valve spacer
VVQ4000–24A–1D
(1, 2)
Double check spacer with
residual pressure exhaust
VVQ4 0 00–25A–1
Built-in silencer (Direct exhaust)
[–S ]
D
U
(1)
For exhaust cleaner mounting
[–S ]
D
U
(1)
(1)
P USH
LO CK
Note 1) Release valve spacer, built-in silencer (direct exhaust), exhaust cleaner mounting and double check spacer for residual pressure exhaust cannot be
combined with external pilot.
Note 2) Can be mounted on L kit only. For other kits, order E type control unit. (Refer to p.1.11-38 to 1.11-41)
1.11-9
13768148.181.png
 
13768148.182.png 13768148.184.png 13768148.185.png 13768148.186.png 13768148.187.png 13768148.188.png 13768148.189.png 13768148.190.png 13768148.191.png 13768148.192.png 13768148.193.png 13768148.002.png 13768148.003.png 13768148.004.png 13768148.005.png 13768148.006.png 13768148.007.png 13768148.008.png 13768148.009.png 13768148.010.png 13768148.011.png 13768148.013.png 13768148.014.png 13768148.015.png 13768148.016.png 13768148.017.png 13768148.018.png 13768148.019.png 13768148.020.png 13768148.021.png 13768148.022.png 13768148.024.png 13768148.025.png 13768148.026.png 13768148.027.png 13768148.028.png 13768148.029.png 13768148.030.png 13768148.031.png 13768148.032.png 13768148.033.png 13768148.035.png 13768148.036.png 13768148.037.png 13768148.038.png 13768148.039.png 13768148.040.png 13768148.041.png 13768148.042.png 13768148.043.png 13768148.044.png 13768148.046.png 13768148.047.png 13768148.048.png 13768148.049.png 13768148.050.png 13768148.051.png 13768148.052.png 13768148.053.png 13768148.054.png 13768148.055.png 13768148.056.png 13768148.057.png 13768148.058.png 13768148.059.png 13768148.060.png 13768148.061.png 13768148.062.png 13768148.063.png 13768148.064.png 13768148.065.png 13768148.067.png 13768148.068.png 13768148.069.png 13768148.070.png 13768148.071.png 13768148.072.png 13768148.073.png 13768148.074.png 13768148.075.png 13768148.076.png 13768148.077.png 13768148.078.png 13768148.079.png 13768148.080.png 13768148.081.png 13768148.082.png 13768148.083.png 13768148.084.png 13768148.085.png 13768148.086.png 13768148.088.png 13768148.089.png 13768148.090.png 13768148.091.png
Series VQ4000
F
Kit (D-sub connector)
V
The D-sub connector permits simple rationalization and installation
labor saving for electrical connection.
The D-sub connector (25 pin std.) conforms with MIL permitting use
of commercial connectors with wide interchangeability.
U side or D side receptacle position can be selected in accordance
with the available mounting space.
Max. 18 stations
Manifold specifications
Porting specifications
Applicable
Max. stations
V
Series
Port
location
Port size
P, R
A, B
V
V
VQ4000
Side
Rc1/2
C8, 10, 12
Rc1/4, 3/8
Rc1/4
16 stations
Bottom
D-sub Connector (25 pin)
V Cable Ass'y
015
030
050
The D-sub connector cable ass'y can be ordered with a manifold part number.
Refer to “How to Order/Manifold”.
Wire color table by terminal number of
D-sub connector cable ass'y:
Terminal No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
Lead wire color
Black
Brown
Red
Orange
Yellow
Pink
Blue
Violet
Gray
White
White
Yellow
Orange
Yellow
Pink
Blue
Violet
Gray
Orange
Red
Brown
Pink
Gray
Black
White
Dot marking
White
Black
Black
Red
Red
Red
Black
Black
White
Black
White
White
Red
Red
White
Multicore vinyl cable
VVRF0.3mm 5 X 25C
D-sub connector cable ass'y (Option) Electric characteristics
Cable
length (L)
Ass'y No.
Note
Item
Property
Conductor resistance
½
65 or less
1.5m
3m
5m
AXT100-DS25-015
AXT100-DS25-030
AXT100-DS25-050
/km, 20˚C
Voltage limit
V, 1 min, AC
Insurance resistance
M ½ km, 20˚C
A bout ø10
Cable 25 core
x 24AWG
1000
* For other commercial connectors, use a 25 pin
female connector made in conformity with
MIL-C-24308.
5 or more
Note) The minimum
bending radius
of D-sub cable
ass'y is 20mm.
2-M2.6 X 0.45
55
14
25
Soket side
1
13
Terminal No.
47.04
How to Order Manifold
VV5Q
4
1
08
C8
F
U
1K
Options
Series
Symbol
Option
None
Exhaust cleaner: For D side mountig
Exhaust cleaner: For U side mountig
Special wiring specification (Other than double wiring)
CD
CU
K
4
VQ4000
Cable (length)
0
1
2
3
(2)
Without cable
With cable (1.5m)
With cable (3m)
With cable (5m)
Manifold
(2)
(3)
1
Plug-in
SB
Built-in silencer (Direct exhaust
from both sides) F/L kits only
Built-in silencer (Direct exhaust from D side)
Built-in silencer (Direct exhaust from U side)
Stations
SD
SU
Connector location
D
U
02 2 stations
Cylinder ports
With One-touch fitting for ø8
With One-touch fitting for ø10
With One-touch fitting for ø12
Rc1/4
Rc3/8
Bottom piping Rc1/4
Mixed size
As optional specifications, the
maximum number of stations
can be increased based on
special wiring specifications.
See p.1.11-11 for details.
D side
U side
Note 1)
When specifying more than one option, combine
symbols in alphabetical order. Example)-CDK
Combination of [C ] and [S ] is not possible.
Specify the wiring specifications by means of the
manifold specification form.
Refer to P.1.11-38 to p.1.11-41 for with control unit.
18 18 stations
C8
C10
C12
02
03
B
CM
Note 2)
Note 3)
U
D
U
D
Note 4)
*
1.11-10
AXT100-DS25-
13768148.092.png 13768148.093.png
 
13768148.094.png
 
13768148.095.png
 
13768148.097.png
 
13768148.098.png
 
13768148.099.png
 
13768148.100.png
 
13768148.101.png
 
13768148.103.png
 
13768148.104.png
 
13768148.105.png 13768148.106.png 13768148.107.png 13768148.108.png 13768148.109.png 13768148.111.png 13768148.112.png 13768148.113.png 13768148.114.png 13768148.115.png 13768148.116.png
Zgłoś jeśli naruszono regulamin