6.3 RV284.pdf
(
633 KB
)
Pobierz
SINGLE CHECK VALVES
RV284A/B
FEATURES
RV284B
High flow capacity, low pressure loss.
BSP or compression connections.
Test point to check for correct operation.
WRc Approved.
RV284A
DZR brass body.
Conforms to BS6282 Part 1.
APPLICATION
The RV284A and RV284B check valves conform to BS6282 Part
1 and are WRc Approved for use in potable water. These valves
can be used on either cold or hot water up to 90˚C and meet the
requirements of the 1989 model water bylaws. The RV284 is
used to prevent the contamination of water by backflow or cross
flow in plumbing systems.
6.3
SINGLE CHECK VALVES
RV284A/B
Installation
The RV284A and RV284B check
valves
should be installed with the
flow in the direction of the arrow on the
body. Care should be taken when using
jointing compounds not to allow excess
material to enter the valves as this
could prevent tight shut-off in reverse
flow conditions. The valves will operate
in any orientation and are silent in
operation. All RV284 single check
valves are provided with a
1
⁄
4
” test point
to ensure correct functioning.
Specification
Maximum flow temperature
: 90˚C
Maximum static pressure
: 16 bar
Body
: DRZ brass, CZ132
Internal components
: WRc listed materials
Approvals
: WRc approved
Standards
: BS6282 Part 1
Connections
:
1
⁄
2
”,
3
⁄
4
”, 1” BSP female
15mm, 22mm, 28mm compression
Dimensions (mm)
PART NO
CONNECTIONS
A
B
C
RV284-
1
⁄
2
A
⁄
2
” female BSP
52
27
27
1
⁄
4
A
⁄
4
” female BSP
63
33
29
3
3
1A
1” female BSP
69
39
32
RV284-
1
⁄
2
B
15mm compression
72
27
27
⁄
4
B
22mm compression
84
36
29
3
1B
28mm compression
89
46
32
Flow Graph
Plik z chomika:
Synthmauro
Inne pliki z tego folderu:
6.3 RV284.pdf
(633 KB)
6.6 TP192.pdf
(434 KB)
6.4 SM192.pdf
(611 KB)
6.5 TM200 - ZD.pdf
(418 KB)
6.2 DO7-ZF.pdf
(497 KB)
Inne foldery tego chomika:
Gas Spares
Heating Controls
Heating Spares
Non-Electric Controls
Smartfit
Zgłoś jeśli