A5.pdf
(
4203 KB
)
Pobierz
ASY10FSACW_p2-p21 (Page 1)
S P L IT T Y P E R O O M A IR
C O N DIT IO N E R
W A L L M O U N T E D
t y p e
Models
Indoor unit
Outdoor unit
RS-9UA
RO-9UA
RS-12UC
RO-12UC
CONTENTS
SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . 1
OUTLINE AND DIMENSIONS . . . . . . . . . . . . . . . 3
REFRIGERANT SYSTEM DIAGRAM . . . . . . . . 5
CIRCUIT DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . 6
DISASSEMBLY ILLUSTRATION . . . . . . . . . . . . . 7
PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
STANDARD ACCESSORIES . . . . . . . . . . . . . . . . 14
1
2003.04.25
A DDIT IO N A L C HA R G E O F R E FR IG E R A N T
(R S -9U A / R O -9U A )
(R S -12U C / R O -12U C )
R efrigerant s uitable for a piping length of 7.5 m is charged in the outdoor unit at the factory .
W hen the piping is longer than 7.5 m , additional charging is neces s ary .
For the additional am ount, s ee the table below .
P IP E L E N G T H
7.5 m
10 m
15 m
150 g
A DDIT IO N A L R E FR IG E R A N T
N one
50 g
B etw een 7.5 m and 15 m , w hen us ing a connection pipe other than that in the table,
charge additional refrigerant w ith 20g /1 m as the criteria.
(T he m ax im um length of piping is 15m . If the units are further apart than this , correct
operation can not be guaranteed.)
2003.04.25
2
DIM E N S IO N S
INDOOR UNIT
U nit : m m
(RS-9UA / RS-12UC)
790
215
OUTDOOR UNIT
(RO-9UA)
440
Drain pipe hold 20
O
500
98
695
250
290
2003.04.25
3
(RO-12UC)
540
120
780
5
5
250
2003.04.25
4