BTI_AMX 3_4_5.pdf

(1220 KB) Pobierz
CAT2006.qxd (Page 1)
FURTIF AMX
STAND-ALONE without safety module
NON-CONTACT AND CODED SAFETY SWITCH :
TOTAL SAFETY IN CATEGORY
TOTAL SAFETY IN CATEGORY 3
Integrated self-control
Detection distance/hysteresis/misalignment :
10 /+2 /±7 (mm)
LED indicating the switch condition
Mounting brackets and moulded cable
Available with a M12 connector (AMX3/ AMX5)
Polycarbonate housing
Available in stainless steel 316L (except for
AMX4)
Protection class IP67
Temperature -20°C to +60°C
SAFETY CATEGORY
AMX3 / AMX4 / AMX5: category 3* according to
EN954-1
AMX4/AMX5 in category 4* with a safety module.
* Regardless of the number of switches in series.
WIRING DIAGRAM
DIMENSIONS
AMX 3
BROWN
LED on door closed
24V AC/DC
23
15
24,4
16
23
13,5
18
10
2A
BLACK
RED
K1
2A/48V
max
K2
WHITE
ORANGE
BLUE
250mA/24V
max.
SELF
CONTROL
0V
cat.3
RECEIVER
RECEIVER
AMX 4
BROWN
24V AC/DC
2A
BLACK
RED
K1
2A/48V
max
2A
GREY
ORANGE
BLUE
K2
2A/48V
max
SELF
CONTROL
0V
cat.3
10,5x4,2
9,5x4,2
13x4,2
10,5x4,2
AMX5
BROWN
24V AC/DC
Standard cable 3/6/12m Diam. 5
MKT : cable 20cm Diam.7
connector M12/8pin
Indicated measures for polycarbonate cases
2A
BLACK
RED
K1
2A/48V
max
PIN DETAILS FOR MKT CONNECTOR
2A
GREY
ORANGE
BLUE
K2
2A/48V
max
FRONT VIEW
AMX3/MKT
FRONT VIEW
AMX5/MKT
1 white: NO1 5 grey: 0V
2 brown: nc 6 pink: NO1
3 blue: NC1 7 green: NC1
4 yellow: +24V 8 red: nc
(nc : non connected)
1 white: NO2 5 grey: 0V
2 brown: NO1 6 pink: NO2
3 green: AUX 7 blue: NO1
4 yellow: +24v 8 red: nc
(nc : non connected)
SELF
CONTROL
2
1
2
1
8
8
0V
3
7
3
7
4
6
4
6
WHITE
250mA/24V
max.
5
5
cat.3
AMX 3 in case of failure
ADVICE
Control of the moving protectors of dangerous
machines with a high authorized misalignment
without any safety module in the electronic board.
AMX 4/5 in case of failure
Our switches are equipped with a 2A fuse in order
to guarantee electrical protection.
14
NON-CONTACT AND CODED SAFETY SWITCH :
388912446.051.png 388912446.056.png 388912446.057.png 388912446.058.png 388912446.001.png 388912446.002.png 388912446.003.png 388912446.004.png 388912446.005.png 388912446.006.png 388912446.007.png 388912446.008.png 388912446.009.png 388912446.010.png 388912446.011.png 388912446.012.png 388912446.013.png 388912446.014.png 388912446.015.png 388912446.016.png 388912446.017.png 388912446.018.png 388912446.019.png 388912446.020.png 388912446.021.png 388912446.022.png 388912446.023.png 388912446.024.png 388912446.025.png 388912446.026.png 388912446.027.png 388912446.028.png 388912446.029.png 388912446.030.png 388912446.031.png 388912446.032.png 388912446.033.png 388912446.034.png 388912446.035.png
DIAGRAMS
APPLICATION DIAGRAMS
ACCESS PROTECTION IN CATEGORY 3
CATEGORY 3 OF POWER PARTS
24Vac/dc
.
Φ
Φ
2
Φ
3
.
.
.
.
AMX3
K1
K2
.
M
3~
cat.3
ACCESS AND EMERGENCY STOP
CATEGORY 3 OF POWER PARTS
24Vac/dc
Φ
1
Φ
2
Φ
.
.
.
.
.
.
K2
AMX3
cat.3 of access
primary safety
.
cat. 2 of an
emergency stop
secondary safety
K1
Sticking
control
E1
E2
A1 A2
M
3~
C
ON
CO13
XXL
C
K2
K1
13
23 V
You should identify the zones to be
protected. Zones can have different
safety levels, we distinguish a primary
and secondary safety
.
cat.3
16
1
3
388912446.036.png 388912446.037.png 388912446.038.png 388912446.039.png
DIAGRAMS
APPLICATION DIAGRAMS
ACCESS PROTECTION IN CATEGORY 3
CATEGORY 3 OF THE POWER PARTS
24Vac/dc
Φ
Φ
Φ
3
.
K2
AMX4
AMX4
K1
THE CATEGORY 3
WITHOUT LIMIT
M
3~
AMX4
AMX4
grey
black
cat.3
24Vac/dc
Φ
1
Φ
2
Φ
AMX4
AMX4
THE CAT.4
WITHOUT
LIMIT
K2
T11
T21 T22 T12
K1
C
AWAX
26XXL
ON
M
3~
24
AMX4
AMX4
K2
14
K1
grey
A2 23 13 V
A1
black
ONLY ONE-
MODULE
cat.4
17
1
2
3
388912446.040.png 388912446.041.png 388912446.042.png 388912446.043.png 388912446.044.png 388912446.045.png
DIAGRAMS
APPLICATION DIAGRAMS
ACCESS PROTECTION IN CATEGORY 3
24Vac/dc
.
.
Φ
Φ
Φ
3
.
.
AMX5
K1
K2
M
3~
cat.3
ACCESS PROTECTION IN CATEGORY 4
The Furtif switches are equip-
ped with a LED indicating the
state of the switch.
24Vac/dc
Φ
1
Φ
2
Φ
3
.
.
K2
AMX5
.
DOOR INDICATION
OR PLC
INFORMATION
.
K1
.
.
M
3~
T11
T21
A1 A2
STICKING
CONTROL
C
AMX5
AWAX
26XXL
ON
THANKS TO THE SELF
CONTROL SYSTEM INTE-
GRATED IN EACH AMX5
SWITCH, ONLY ONE SAFETY
MODULE OF CAT. 4 IS
ENOUGH TO REACH A SAFE-
TY CAT. 4 OF THE WHOLE
INSTALLATION
23
K2
13
OF F
grey
T12
K1
black
T22
24 14 V
cat.4
18
1
2
388912446.046.png 388912446.047.png 388912446.048.png 388912446.049.png 388912446.050.png 388912446.052.png 388912446.053.png 388912446.054.png 388912446.055.png
Zgłoś jeśli naruszono regulamin