802D_DIA(2).pdf

(686 KB) Pobierz
Diagnostics Guide 10/2002 Edition
sinumerik
SINUMERIK 802D
921256440.018.png
 
921256440.019.png
1
Alarms
2
Glossary /
Abbreviations
SINUMERIK 802D
Diagnostics Guide
User Documentation
Valid for
Control
Software version
SINUMERIK 802D
as of 1
10.02 Edition
921256440.020.png 921256440.001.png 921256440.002.png 921256440.003.png
 
SINUMERIK® Documentation
Printing history
The editions listed below have been published prior to the current edition.
The status of each edition is shown by the code in the "Remarks" column.
Status code in the "Remarks" column:
A ....
New documentation
B ....
Unrevised reprint with new order number
C ....
Revised version with new issue
If factual changes have been made on the page since the last edition, this is indicated by a new
edition coding in the header on that page.
Edition
Order No.
Note
11.00
6FC5698-2AA20-0BP0
A
10.02
6FC5698-2AA20-0BP1
C
Tested Siemens quality for software and training
to DIN ISO 9001, Reg. No. 2160-01
Other functions not described in this documentation can possibly also be per-
formed on the control system. However, the customer is not entitled to demand
these functions when the new equipment is supplied or servicing is carried out.
This publication was created using WinWord V 8
and Designer V 6.0.
This document may not be reproduced or communicated to others, nor may its
contents be exploited or passed on to third parties, unless expressly permitted.
Non-compliance will result in a liability for damages. All rights reserved, especially
in the case of the granting of a patent or design registration.© Siemens AG 2003.
All rights reserved.
Although we have checked the contents of this publication for agreement with the
hardware and software described, since differences cannot be totally ruled
out.The information in this publication is checked at regular intervals and neces-
sary corrections will be included in the next releases.Suggestions for improvement
are always welcome.Subject to change without prior notice.
Order No. 6FC5698-2AA20-0BP1
Printed in the Federal Republic of Germany
Siemens-Aktiengesellschaft
10.02
Preface
The present description is intended to be used as a reference manual. It
allows the operator on the machine tool to:
-
access special cases in the operation of the machine correctly;
-
to learn the response of the system/installation to the particular spe-
cial case;
-
to use the possibilities of continuing work after the special case;
-
to follow notes for further references.
Object of the present description are the alarms occurring in the areas
NC kernel (NCK), Profibus, cycles and PLC.
Further alarms may occur in the HMI area (Human Machine Interface).
They are announced to the user by self-explaining alarm lines displayed
on the operator panel. These alarms are not part of this Diagnostics
Guide.
For special cases in conjunction with the integrated PLC, please refer to
the relevant SIMATIC S7-200 system documentation.
Scope
Sorting
The alarms are sorted in the Diagnostics Guide by ascending alarm
numbers with gaps between them.
Safety
Danger
Please always check the situation of the particular system/installation
carefully on the basis of the alarms occurred. Eliminate the causes for
the occurrence of the alarms and acknowledge them as described.
Otherwise, danger will result for machine, workpiece, saved settings
and - under certain circumstances - even for your health.
NC alarms
Table 1_1
Alarm number ranges
000 000 - 009 999
General alarms
010 000 - 019 999
Channel alarms
020 000 - 029 999
Axis / spindle alarms
030 000 - 099 999
Functional alarms
060 000 - 064 999
SIEMENS cycle alarms
065 000 - 069 999
User cycle alarms
© Siemens AG 2003 All Rights Reserved
6FC5698-2AA20-0BP1
v
SINUMERIK 802D (DG)
921256440.004.png 921256440.005.png 921256440.006.png 921256440.007.png 921256440.008.png 921256440.009.png 921256440.010.png 921256440.011.png 921256440.012.png 921256440.013.png 921256440.014.png 921256440.015.png 921256440.016.png 921256440.017.png
 
Zgłoś jeśli naruszono regulamin