SEISMIC ANALYSIS MODELING
TO SATISFY BUILDING CODES
The Current Building Codes Use the Terminology
Principal Direction without A Unique Definition
17.1. INTRODUCTION
Currently a three-dimensional dynamic analysis is required for a large number of
different types of structural systems that are constructed in Seismic Zones 2, 3 and 4
[1]. The lateral force requirements suggest several methods that can be used to
determine the distribution of seismic forces within a structure. However, these
guidelines are not unique and need further interpretations.
The major advantage of using the forces obtained from a dynamic analysis as the
basis for a structural design is that the vertical distribution of forces may be
significantly different from the forces obtained from an equivalent static load
analysis. Consequently, the use of dynamic analysis will produce structural designs
that are more earthquake resistant than structures designed using static loads.
For many years, approximate two-dimensional static load was acceptable as the
basis for seismic design in many geographical areas and for most types of structural
systems. During the past twenty years, due to the increasing availability of modern
digital computers, most engineers have had experience with the static load analysis
of three dimensional structures. However, few engineers, and the writers of the
current building code, have had experience with the three dimensional dynamic
2
STATIC AND DYNAMIC ANALYSIS
response analysis. Therefore, the interpretation of the dynamic analysis requirement
of the current code represents a new challenge to most structural engineers.
The current code allows the results obtained from a dynamic analysis to be
normalized so that the maximum dynamic base shear is equal to the base shear
obtained from a simple two-dimensional static load analysis. Most members of the
profession realize that there is no theoretical foundation for this approach.
However, for the purpose of selecting the magnitude of the dynamic loading that will
satisfy the code requirements, this approach can be accepted, in a modified form,
until a more rational method is adopted.
The calculation of the “design base shears” is simple and the variables are defined in
the code. It is of interest to note, however, that the basic magnitude of the seismic
loads has not changed significantly from previous codes. The major change is that
“dynamic methods of analysis” must be used in the “principal directions” of the
structure. The present code does not state how to define the principal directions for
a three dimensional structure of arbitrary geometric shape. Since the design base
shear can be different in each direction, this “scaled spectra” approach can produce
a different input motion for each direction, for both regular and irregular structures.
Therefore, the current code dynamic analysis approach can result in a structural
design which is relatively “weak” in one direction . The method of dynamic
analysis proposed in this chapter results in a structural design that has equal
resistance in all directions.
In addition, the maximum possible design base shear, which is defined by the present
code, is approximately 35 percent of the weight of the structure. For many
structures, it is less than 10 percent. It is generally recognized that this force level is
small when compared to measured earthquake forces. Therefore, the use of this
design base shear requires that substantial ductility be designed into the structure.
The definition of an irregular structure, the scaling of the dynamic base shears to the
static base shears for each direction, the application of accidental torsional loads and
the treatment of orthogonal loading effects are areas which are not clearly defined in
the current building code. The purpose of this section is to present one method of
three dimensional seismic analysis that will satisfy the Lateral Force Requirements
of the code. The method is based on the response spectral shapes defined in the code
and previously published and accepted computational procedures.
SEISMIC ANALYSIS MODELING
3
17.2. THREE DIMENSIONAL COMPUTER MODEL
Real and accidental torsional effects must be considered for all structures.
Therefore, all structures must be treated as three dimensional systems. Structures
with irregular plans, vertical setbacks or soft stories will cause no additional
problems if a realistic three dimensional computer model is created. This model
should be developed in the very early stages of design since it can be used for static
wind and vertical loads, as well as dynamic seismic loads.
Only structural elements with significant stiffness and ductility should be modeled.
Non-structural brittle components can be neglected. However, shearing, axial
deformations and non-center line dimensions can be considered in all members
without a significant increase in computational effort by most modern computer
programs. The rigid, in-plane approximation of floor systems has been shown to be
acceptable for most buildings. For the purpose of elastic dynamic analysis, gross
concrete sections, neglecting the stiffness of the steel, are normally used. A cracked
section mode should be used to check the final design.
The P-Delta effects should be included in all structural models. It has been shown in
Chapter 11 that these second order effects can be considered, without iteration, for
both static and dynamic loads. The effect of including P-Delta displacements in a
dynamic analysis results in a small increase in the period of all modes. In addition
to being more accurate, an additional advantage of automatically including P-Delta
effects is that the moment magnification factor for all members can be taken as unity
in all subsequent stress checks.
The mass of the structure can be estimated with a high degree of accuracy. The
major assumption required is to estimate the amount of live load to be included as
added mass. For certain types of structures it may be necessary to conduct several
analyses with different values of mass. The lumped mass approximation has proven
to be accurate. In the case of the rigid diaphragm approximation, the rotational
mass moment of inertia must be calculated.
The stiffness of the foundation region of most structures can be modeled by massless
structural elements. It is particularly important to model the stiffness of piles and
the rotational stiffness at the base of shear walls.
4
STATIC AND DYNAMIC ANALYSIS
The computer model for static loads only should be executed prior to conducting a
dynamic analysis. Equilibrium can be checked and various modeling
approximations can be verified with simple static load patterns. The results of a
dynamic analysis are generally very complex and the forces obtained from a
response spectra analysis are always positive. Therefore, dynamic equilibrium is
almost impossible to check. However, it is relatively simple to check energy
balances in both linear and nonlinear analysis.
17.3. THREE DIMENSIONAL MODE SHAPES AND FREQUENCIES
The first step in the dynamic analysis of a structural model is the calculation of the
three dimensional mode shapes and natural frequencies of vibration. Within the past
several years, very efficient computational methods have been developed which have
greatly decreased the computational requirements associated with the calculation of
orthogonal shape functions as presented in Chapter 14. It has been demonstrated
that load-dependent Ritz vectors, which can be generated with a minimum of
numerical effort, produce more accurate results when used for a seismic dynamic
analysis than if the exact free-vibration mode shapes are used.
Therefore, a dynamic response spectra analysis can be conducted with
approximately twice the computer time requirements of a static load analysis. Since
systems with over 60,000 dynamic degrees-of-freedom can be solved within a few
hours on personal computers, there is not a significant increase in cost between a
static and a dynamic analysis. The major cost is the “man hours” required to
produce the three dimensional computer model that is necessary for a static or a
dynamic analysis.
In order to illustrate the dynamic properties of the three dimensional structure, the
mode shapes and frequencies are calculated for the irregular, eight story, 80 foot tall
building shown in Figure 17.1. This building is a concrete structure with several
hundred degrees-of-freedom. However, the three components of mass are lumped at
each of the eight floor levels. Therefore, only 24 three dimensional mode shapes are
possible.
SEISMIC ANALYSIS MODELING
5
Roof
8th
10’ Typ.
7th
6th
5th
4th
3rd
2nd
Base
Figure 17.1. Example of Eight Story Irregular Building
Each three dimensional mode shape of a structure may have displacement
components in all directions. For the special case of a symmetrical structure, the
mode shapes are uncoupled and will have displacement in one direction only. Since
each mode can be considered to be a deflection due to a set of static loads, six base
reaction forces can be calculated for each mode shape. For the structure shown in
Figure 17.1, Table 17.1 summarizes the two base reactions and three overturning
moments associated with each mode shape. Since vertical mass has been neglected
there is no vertical reaction. The magnitudes of the forces and moments have no
meaning since the amplitude of a mode shape can be normalized to any value.
However, the relative values of the different components of the shears and moments
associated with each mode are of considerable value. The modes with a large
torsional component are highlighted in bold .