REKAN98GBB.PDF

(10 KB) Pobierz
REKAN98GBB.PDF
SPECIFIC VEHICLE ALARM FITTING INSTRUCTIONS REV. 00
www.cobra.it
RENAULT
MOD. KANGOO YEAR 98
PETROL
DIESEL
X
MAKE
ALARM/SIREN
POSITION
Position the compact alarms and the sirens near the left or right lateral headlamp
in the engine compartment.
POWER SUPPLY
+ 30: connect to the wire at the position nr. 1 of the 2 way grey connector coming
out of the ignition key.
- 31: connect with a ring terminal to one of the terminals located on the car body
behind the left lateral bulkhead, drivers side.
IGNITION WIRE
+ 15/54: connect to the wire at the position nr 2 of the 2 way grey connector
located in the lower part of the ignition key.
DIRECTION INDICATORS
Connect to the wires at the positions nr. 2 and nr. 4 of the multiway black
connector coming out of the light switch.
ELECTRIC WINDOWS
Positive control signal
Right front window:
cut the wire marked nr. 608 located in the wiring harness coming out of the
connector of the switch in the central consolle.
Left front window:
cut the wire marked nr. 6040 located in the wiring harness coming out of the door,
drivers side.
CENTRAL DOORS LOCKING
Negative control signal
Connect to the wires at the positions nr. 6 (lock) and nr. 9 (unlock) located in the
connector of the central door locking unit under the bulkhead bolted between the
wheelhouse and the partition and between passenger compartment and loading
compartment.
For Art. 0144 antitheft
Connect the VIOLET/WHITE wire (0144) to the wire at the position B9 and the
ORANGE/WHITE wire (0144) to the wire at the position B8, the VIOLET wire
(0144) to the wire at the position B2 and the ORANGE wire (0144) to the wire at
the position B5 in the 18 way blue connector coming out of the central doors
locking unit.
IMMOBILISATION POINT
Vehicle with serial immobiliser (Clavier).
BONNET SWITCH
Install an additional switch on the front wheelhouse, drivers side.
DOORS SWITCH
Connect to the wire at the position B3 of the 18 way blue connector coming out of
the central door locking unit.
Note: This information is not binding, therefore it must be considered only an example for installation purposes that must be executed
as per the instructions given on the product installation manual.
rekan98gbb.doc