s202s02.pdf

(57 KB) Pobierz
199641656 UNPDF
S102S01/S102S02/S202S01/S202S02
S102S01/S102S02
S202S01/S202S02
SIP Type SSR for Medium
Power Control
n
Features
n
Outline Dimensions
( Unit : mm )
1. High radiation resin mold package
* The metal parts marked *
2. RMS ON-state current
I T : 8 Arms at T C <= 80˚C
( With heat sink )
3. Built-in zero-cross circuit
(S102S02/S202S02 )
4. High repetitive peak OFF-state voltage
S102S01/S102S02 V DRM : MIN. 400V
S202S01/S202S02 V DRM : MIN. 600V
5. Isolation voltage between input and output
( V iso
Do not allow external connection.
( ) : Typical dimensions
18.5 ± 0.2
16.4 ± 0.3
f
3.2 ± 0.2
5.5 ± 0 .2
A ( Model No. )
B
*
S102S01
8A125VAC
S102S02
S202S01
8A250VAC
S202S02
A
: 4 000V rms )
B
6. Approved by CSA, No. LR63705
4 - 1.1 ± 0.2
4 - 1.25 ± 0.3
4 - 0.8 ± 0.2
+
-
Recognized by UL, file No. E94758
123 4
n
Applications
1. Automatic vending machines, programmable
controllers
2. Amusement equipment
( 5.08 ) 7.62 )
( 2.54 )
0.6 ± 0.1
(1.4)
Internal connection diagram
S102S01 / S202S01
S102S02 / S202S02
n
Model Line-ups
Zero-Cross
Circuit
For 100V lines
For 200V lines
12 34
12
34
For phase control
No built-in zero-cross circuit
S102S01
S202S01
1 Output ( Triac T2 )
1 Output ( Triac T2 )
2 Output (Triac T1 )
2 Output (Triac T1 )
3 Input ( + )
3 Input ( + )
Built-in zero-cross circuit
S102S02
S202S02
4 Input ( - )
4 Input ( - )
n
Absolute Maximum Ratings
( Ta = 25˚C )
Parameter
Symbol
Rating
Unit
*1 T C <= 80˚C
*2 50Hz sine wave, T j =25˚C
start
*3 60Hz AC for 1 minute,
S102S01
S102S02
S202S01
S202S02
Input
Forward current
I F
50
mA
Reverse voltage
V R
6
V
40 to 60 % RH, Apply voltages
between input and output, by
the dielectric withstand
voltage tester with zero-
cross circuit.
( Input and output shall be
*1 RMS ON-state current
I T
8
A rms
*2 Peak one cycle surge current
I surge
80
A
Output
Repetitive peak OFF-state voltage
V DRM
400
600
V
Non-repetitive peak OFF-state voltage
current
V DSM
400
600
V
shorted respectively ) .
Critical rate of rise of ON-state
dI/dt
50
A/m s
(Note)
When the isolation voltage
Operating frequency
f
45 to 65
Hz
is necessary at using external
heat sink, please use the
*3 Isolation voltage
V iso
4 000
V rms
Operating temperature
T opr
- 25 to + 100
˚C
insulation sheet.
Storage temperature
T stg
- 30 to + 125
˚C
*4 For 10 seconds
*4 Soldering temperature
T sol
260
˚C
“ In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that occur in equipment using any of SHARP's devices, shown in catalogs,
data books, etc. Contact SHARP in order to obtain the latest version of the device specification sheets before using any SHARP's device. ”
are common to terminal 1 .
h
199641656.005.png 199641656.006.png 199641656.007.png 199641656.008.png 199641656.001.png
S102S01/S102S02/S202S01/S202S02
n
Electro-optical Characteristics
( Ta = 25˚C )
Parameter
Symbol
V F
I R
I DRM
V T
I H
Conditions
I F = 20mA
V R =3V
V D =V DRM
MIN.
TYP.
MAX.
Unit
Input
Forward voltage
Reverse current
-
1.2
1.4
V
-
-
10 - 4
A
Repetitive peak OFF-state current
ON-state voltage
-
-
10 - 4
A
Resistance load
-
-
1.5
V rms
I F = 20mA, I T = 2Arms
Holding current
-
-
-
50
mA
Output
Critical rate of rise of OFF-state voltage
Critical rate of rise of commutating
OFF-state voltage
dV/dt
V D = 2/3 • V DRM
30
-
-
V/m s
( dV/dt ) C
T j = 125˚C, dI T /dt= - 4.0A/ms,
V D = 400V
5
-
-
V/m s
Zero-cross voltage
S102S02
S202S02
S102S01
S202S01
S102S02
S202S02
V OX
I F = 8mA
V D = 12V, R L =30W
V D = 6V, R L =30W
-
-
35
V
Minimum
trigger
current
I FT
-
-
8
mA
-
-
8
mA
Transfer
charac-
teristics
Isolation resistance
R ISO
DC500V, 40 to 60 % RH
10 10
-
-
W
Turn-on
time
S102S01
S202S01
S102S02
S202S02
t on
AC 50Hz
-
-
1
ms
-
-
10
ms
Turn-off time
Thermal resistance ( Between junction and case )
Thermal resistance ( Between junction and ambience )
t off
R th ( j-c )
R th (j-a)
-
-
-
10
ms
-
-
-
4.5
-
˚C/W
-
40
-
˚C/W
Fig. 1 RMS ON-state Current vs.
Ambient Temperature
10
( 1 ) With infinite heat sink
( 2) With heat sink ( 200 x 200 x 2 mm Al plate )
( 3) With heat sink ( 100 x 100 x 2 mm Al plate )
( 4 ) With heat sink ( 75 x 75 x 2 mm Al plate )
( 5 ) With heat sink ( 50 x 50 x 2 mm Al plate )
( 6 ) Without heat sink
( Note) With the Al heat sink set up vertically,tighten
the device at the center of the Al heat sink
9
8
( 1 )
(2)
7
(5)
( 4 )
( 3 )
6
with a torque of 0.4N • m and apply thermal
5
conductive silicone grease on the heat sink
mounting plate. Forcible cooling shall not be
4
carried out.
(6)
3
2
1
0
- 25
0
25
50
75
100
125
Ambient temperature T a ( ˚C )
199641656.002.png
S102S01/S102S02/S202S01/S202S02
Fig. 2 RMS ON-state Current vs.
Case Temperature
Fig. 3 Forward Current vs.
Ambient Temperature
10
60
8
50
40
6
30
4
20
2
10
0
- 25
0
25
50
75
100
125
0
- 25
0
25
50
75
100
125
Case temperature T (˚C)
C
Ambient temperature T a (˚C)
Fig. 4 Forward Current vs. Forward Voltage
Fig. 5 Surge Current vs. Power-on Cycle
200
100
100
f= 50Hz
T j = 25˚C Start
T a = 100˚C
80
50
20
75˚C
50˚C
25˚C
0˚C
60
10
- 25˚C
40
5
20
2
1
0
1.0
2.0
0
1
2
5
10
20
50
100
Forward voltage V F ( V )
Power-on cycle ( Times )
Fig. 6 Maximum ON-state Power Dissipation
vs. RMS ON-state Current ( Typical Value )
Fig. 7 Minimum Trigger Current vs.
Ambient Temperature ( Typical Value )
20
10
T a = 25˚C
V D = 12V
18
( S102S01/S202S01 )
V D =6V
16
8
(S102S02/S202S02 )
14
R L =30
W
S102S01
S202S01
12
6
10
8
4
S102S02
S202S02
6
4
2
2
0
0
2
4
6
8
10
12
- 25
0
25
50
75
100
RMS ON-state current I T ( A rms )
Ambient temperature T a ( ˚C )
0
199641656.003.png
S102S01/S102S02/S202S01/S202S02
Fig. 8 Repetitive Peak OFF-state Current
vs. Ambient Temperature ( Typical Value )
10 -4
V D = 400V
V D = 600V
(S102S01/S102S02 )
10 -5
( S202S01/S202S02 )
S102S02
10 -6
S202S02
S102S01
10 -7
S202S01
10 -8
10 -9
0
25
50
75
100
Ambient temperature T a ( ˚C )
l Please refer to the chapter “ Precautions for Use ”
- 25
199641656.004.png
Zgłoś jeśli naruszono regulamin